Literature DB >> 11404133

Left ventricular architecture after valve replacement due to critical aortic stenosis: an approach to dis-/qualify the myth of valve prosthesis-patient mismatch?

I Knez1, R Rienmüller, R Maier, P Rehak, B Schröttner, H Mächler, M Anelli-Monti, B Rigler.   

Abstract

OBJECTIVES: Left ventricular hypertrophy in patients with critical aortic stenosis (AS) is an adaptive process that compensates for high intracavitary pressure and reduces systolic wall stress followed by an increase in myocardial masses. In the present prospective clinical trial, we investigated long-term compensatory changes in left ventricular geometry and function after aortic valve replacement using mechanical bileaflet prostheses with the main emphasis on the small-sized aortic annulus and valve prosthesis-patient mismatch.
METHODS: A total of 58 patients with critical AS were assigned to the following groups according to the predictive value of prosthetic valve area index (VAI): group EXMIS: 29 patients (VAI < or =0.99), expected mismatch; group NOMIS: 29 patients (VAI < or =0.99), no mismatch. At controls T(0) (before operation/operation (OP), T(1) and T(2) (4 and 20 months after OP) the left ventricular geometry was recorded by means of Imatron electron beam tomography and the transprosthetic velocities were measured by echocardiography.
RESULTS: Statistical analysis showed a consistent reduction in the absolute (P=0.04) and indexed (P=0.04) left ventricular myocardial mass for both cohorts; furthermore, there was a significant difference between EXMIS and NOMIS patients concerning the factors, time and mass reduction (P=0.005), because of distinct baselines. A logistic regression report revealed preoperative cardiac output, absolute left ventricular myocardial mass, perfusion, body surface area and the native valve orifice area as predicting coefficients and factors for a minimum mass reduction of 25%. We explain a mathematical formula that turned out to be the most sensitive for correctly classified factors.
CONCLUSIONS: The left ventricular geometry and transprosthetic velocities resulted in the same postoperative recovery for both EXMIS and NOMIS patients. The presented data showed that valve prosthesis-patient mismatch had no influence in several stepwise logistic regression models. We conclude that modern mechanical bileaflet prostheses allow both acceptable hemodynamics and recovery of left ventricular hypertrophy, even in small aortic annuli.

Entities:  

Mesh:

Year:  2001        PMID: 11404133     DOI: 10.1016/s1010-7940(01)00683-2

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?

Authors:  Sabine Bleiziffer; Walter B Eichinger; Ina Hettich; Ralf Guenzinger; Daniel Ruzicka; Robert Bauernschmitt; Ruediger Lange
Journal:  Heart       Date:  2006-12-12       Impact factor: 5.994

3.  Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis.

Authors:  Edvin Prifti; Massimo Bonacchi; Fadil Ademaj; Gabriele Giunti; Giampiero Esposito; Arben Baboci; Gani Bajraktari; Altin Veshti; Aurel Demiraj; Vittorio Vanini
Journal:  J Cardiothorac Surg       Date:  2015-11-06       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.