Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump.

C Göbel1, A Arvand, R Eilers, O Marseille, C Bals, B Meyns, W Flameng, G Rau, H Reul.   

Abstract

The DeltaStream blood pump has been developed for extracorporeal circulation with one focus on potential integration into simplified bypass systems (SBS). Its small size and an embedded electric motor are the basic pump properties. A variation of the impeller design has been performed to optimize hydraulic and hematologic characteristics. A simple impeller design was developed which allows flow and pressure generation for cardiopulmonary bypass applications. The option of a pulsatile flow mode for ventricular assist device applications also was demonstrated in vitro. Impeller washout holes were implemented to improve nonthrombogenicity. The pump was investigated for potential thermal hazards for blood caused by the integrated electric motor. It could be demonstrated that there is no thermal risk associated with this design. Durability tests were performed to assess the lifetime of the pump especially with regard to the incorporated polymeric seal. Seal lifetimes of up to 28 days were achieved using different blood substitutes. In animal tests using either the pump as a single device or in an SBS setup, biocompatibility, low hemolysis, and nonthrombogenicity were demonstrated. In summary, the DeltaStream pump shows great potential for different extracorporeal perfusion applications. Besides heart-lung machine and SBS applications, ventricular assist and extracorporeal membrane oxygenation up to several days also appear promising as potential applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11403664     DOI: 10.1046/j.1525-1594.2001.025005358.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  6 in total

1.  Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support.

Authors:  Yubing Shi; Alistair G Brown; Patricia V Lawford; Andreas Arndt; Peter Nuesser; D Rodney Hose
Journal:  Interface Focus       Date:  2011-03-02       Impact factor: 3.906

2.  Robust and self-tuning blood flow control during extracorporeal circulation in the presence of system parameter uncertainties.

Authors:  B J E Misgeld; J Werner; M Hexamer
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 2.602

3.  Development of Inspired Therapeutics Pediatric VAD: Benchtop Evaluation of Impeller Performance and Torques for MagLev Motor Design.

Authors:  Landon H Tompkins; Steven R Prina; Barry N Gellman; Gino F Morello; Thomas Roussel; Jonathan A Kopechek; Stuart J Williams; Priscilla C Petit; Mark S Slaughter; Steven C Koenig; Kurt A Dasse
Journal:  Cardiovasc Eng Technol       Date:  2021-09-13       Impact factor: 2.305

4.  Hemolysis caused by surface roughness under shear flow.

Authors:  Osamu Maruyama; Yusuke Numata; Masahiro Nishida; Takashi Yamane; Ikuya Oshima; Yoshikazu Adachi; Toru Masuzawa
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.385

5.  Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change.

Authors:  Hyuk Choi; Seung Hoon Paik; Kwang Ho Lee; Byoung Goo Min; Yong Soon Won
Journal:  Med Biol Eng Comput       Date:  2007-08-25       Impact factor: 3.079

6.  Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump.

Authors:  Landon H Tompkins; Barry N Gellman; Gino F Morello; Steven R Prina; Thomas J Roussel; Jonathan A Kopechek; Priscilla C Petit; Mark S Slaughter; Steven C Koenig; Kurt A Dasse
Journal:  ASAIO J       Date:  2021-09-01       Impact factor: 3.826

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.