Literature DB >> 11401945

Assessment of global atrial fibrillation organization to optimize timing of atrial defibrillation.

T H Everett1, J R Moorman, L C Kok, J G Akar, D E Haines.   

Abstract

BACKGROUND: We hypothesized that frequency domain analysis of a wide bipolar interatrial electrogram describes the global organization of atrial fibrillation (AF) and should vary over time. By timing shocks to periods of high organization of AF, cardioversion efficacy should improve. METHODS AND
RESULTS: A total of 15 dogs (weight, 28.2+/-3.4 kg) were rapidly paced for 48 to 72 hours to induce AF. Coil electrodes with a surface area of 1.80 cm(2) were then placed in the left and right atria to form a wide bipole. Wide bipolar electrograms were digitally filtered, and a fast Fourier transform was performed over a sliding 2-s window every 0.5 s. The organization index (OI) was calculated as the ratio of the area of the dominant peak and its harmonics to the total area of the magnitude spectrum. The atrial defibrillation threshold (ADFT(50)) was determined using a 3-ms/3-ms biphasic shock and an up-down-up protocol. Additional shocks with higher and lower energies were delivered in a random sequence to develop a distribution curve. The OI varied over time, with a mean of 0.42+/-0.03, a maximum of 0.65+/-0.07, and a minimum of 0.20+/-0.06. The OI changed rapidly, with durations of high organization (OI>0.5) ranging from 1 to 5 s. The ADFT(50) for QRS complex-synchronized shocks was 183+/-56 V, versus 142+/-49 V for shocks synchronized to an OI>0.5 (P<0.001). The distribution curve shifted leftward when shocks were synchronized to an OI>0.5.
CONCLUSIONS: AF signals show a high degree of variability. Shock efficacy is increased when shocks are delivered during periods of high AF organization as determined by the OI method.

Entities:  

Mesh:

Year:  2001        PMID: 11401945     DOI: 10.1161/01.cir.103.23.2857

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  23 in total

Review 1.  New technologies of internal defibrillation.

Authors:  Derek J Dosdall; Raymond E Ideker
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

2.  Can one detect atrial fibrillation using a wrist-type photoplethysmographic device?

Authors:  Sibylle Fallet; Mathieu Lemay; Philippe Renevey; Célestin Leupi; Etienne Pruvot; Jean-Marc Vesin
Journal:  Med Biol Eng Comput       Date:  2018-09-15       Impact factor: 2.602

3.  Structural atrial remodeling alters the substrate and spatiotemporal organization of atrial fibrillation: a comparison in canine models of structural and electrical atrial remodeling.

Authors:  Thomas H Everett; Emily E Wilson; Sander Verheule; Jose M Guerra; Scott Foreman; Jeffrey E Olgin
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-07-28       Impact factor: 4.733

4.  Mechanisms of ventricular fibrillation in canine models of congestive heart failure and ischemia assessed by in vivo noncontact mapping.

Authors:  Thomas H Everett; Emily E Wilson; Scott Foreman; Jeffrey E Olgin
Journal:  Circulation       Date:  2005-09-06       Impact factor: 29.690

5.  Evolution of activation patterns during long-duration ventricular fibrillation in pigs.

Authors:  Kang-An Cheng; Derek J Dosdall; Li Li; Jack M Rogers; Raymond E Ideker; Jian Huang
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-12-16       Impact factor: 4.733

6.  Transmural characteristics of atrial fibrillation in canine models of structural and electrical atrial remodeling assessed by simultaneous epicardial and endocardial mapping.

Authors:  Thomas H Everett; Emily E Wilson; George S Hulley; Jeffrey E Olgin
Journal:  Heart Rhythm       Date:  2010-01-11       Impact factor: 6.343

7.  Comparison of spectral estimators for characterizing fractionated atrial electrograms.

Authors:  Edward J Ciaccio; Angelo B Biviano; Hasan Garan
Journal:  Biomed Eng Online       Date:  2013-07-16       Impact factor: 2.819

8.  Differences in repeating patterns of complex fractionated left atrial electrograms in longstanding persistent atrial fibrillation as compared with paroxysmal atrial fibrillation.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; John A Vest; Alok Gambhir; Andrew J Einstein; Hasan Garan
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-05-02

9.  Right atrial organization and wavefront analysis in atrial fibrillation.

Authors:  Ulrike Richter; Andreas Bollmann; Daniela Husser; Martin Stridh
Journal:  Med Biol Eng Comput       Date:  2009-10-15       Impact factor: 2.602

10.  Minimum energy single-shock internal atrial defibrillation in sheep.

Authors:  Amy M Goodman; Merlise A Clyde; Donald S Burdick; Salim F Idriss; Patrick D Wolf
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.