Literature DB >> 11390560

Blind separation of cardiac components and extraction of input function from H(2)(15)O dynamic myocardial PET using independent component analysis.

J S Lee1, D S Lee, J Y Ahn, G J Cheon, S K Kim, J S Yeo, K Seo, K S Park, J K Chung, M C Lee.   

Abstract

UNLABELLED: The independent component analysis (ICA) method is suggested to be useful for separation of the ventricles and the myocardium and for extraction of the left ventricular input function from the dynamic H(2)(15)O myocardial PET. The ICA-generated input function was validated with the sampling method, and the myocardial blood flow (MBF) calculated with this input function was compared with the microsphere results.
METHODS: We assumed that the elementary activities of the ventricular pools and the myocardium were spatially independent and that the mixture of them composed dynamic PET image frames. The independent components were estimated by recursively minimizing the mutual information (measure of dependence) between the components. The ICA-generated input functions were compared with invasively derived arterial blood samples. Moreover, the regional MBF calculated using the ICA-generated input functions and single-compartment model was correlated with the results obtained from the radiolabeled microspheres.
RESULTS: The ventricles and the myocardium were successfully separated in all cases within a short computation time (<15 s). The ICA-generated input functions displayed shapes similar to those obtained by arterial sampling except that they had a smoother tail than those obtained by sampling, which meant that ICA removed the statistical noise from the time--activity curves. The ICA-generated input function showed a longer time delay of peaks than those obtained by arterial sampling. MBFs estimated using the ICA-generated input functions ranged from 1.10 to approximately 2.52 mL/min/g at rest and from 1.69 to approximately 8.00 mL/min/g after stress and correlated well with those calculated with microspheres (y = 0.45 + 0.98x; r = 0.95, P < 0.000).
CONCLUSION: ICA, a rapid and reliable method for extraction of the pure physiologic components, was a valid and useful method for quantification of the regional MBF using H(2)(15)O PET.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11390560

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  Estimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data.

Authors:  Yu-Hua Fang; Tsair Kao; Ren-Shyan Liu; Liang-Chih Wu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-23       Impact factor: 9.236

2.  Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information.

Authors:  Anu Juslin; Jyrki Lötjönen; Sergey V Nesterov; Kari Kalliokoski; Juhani Knuuti; Ulla Ruotsalainen
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

Review 3.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

Review 4.  Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses.

Authors:  Seongho Seo; Su Jin Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Neurosci Bull       Date:  2014-09-28       Impact factor: 5.203

5.  Simultaneous evaluation of myocardial blood flow, cardiac function and lung water content using [15O]H2O and positron emission tomography.

Authors:  Alexandru Naum; Helena Tuunanen; Erik Engblom; Vesa Oikonen; Hannu Sipilä; Patricia Iozzo; Pirjo Nuutila; Juhani Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-10-24       Impact factor: 9.236

Review 6.  KSNM60 in Cardiology: Regrowth After a Long Pause.

Authors:  Sang-Geon Cho; Eun Jung Kong; Won Jun Kang; Jin Chul Paeng; Hee-Seung Henry Bom; Ihnho Cho
Journal:  Nucl Med Mol Imaging       Date:  2021-06-08

7.  Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET.

Authors:  Yanguang Lin; Justin P Haldar; Quanzheng Li; Peter S Conti; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2013-11-07       Impact factor: 10.048

8.  Kinetic quantitation of cerebral PET-FDG studies without concurrent blood sampling: statistical recovery of the arterial input function.

Authors:  F O'Sullivan; J Kirrane; M Muzi; J N O'Sullivan; A M Spence; D A Mankoff; K A Krohn
Journal:  IEEE Trans Med Imaging       Date:  2009-08-25       Impact factor: 10.048

9.  Parametric image of myocardial blood flow generated from dynamic H2(15)O PET using factor analysis and cluster analysis.

Authors:  J S Lee; D S Lee; J Y Ahn; G J Cheon; S-K Kim; J S Yeo; K S Park; J-K Chung; M C Lee
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 3.079

10.  Analysis and interpretation of dynamic FDG PET oncological studies using data reduction techniques.

Authors:  Sotiris Pavlopoulos; Trias Thireou; George Kontaxakis; Andres Santos
Journal:  Biomed Eng Online       Date:  2007-10-03       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.