Literature DB >> 11388579

UK audit and analysis of quantitative parameters obtained from gamma camera renography.

A S Houston1, D R Whalley, J V Skrypniuk, P H Jarritt, J S Fleming, P S Cosgriff.   

Abstract

The purpose of this study was to perform an audit of quantitative values obtained from gamma camera renography in the UK. Ten patient image sequences representing normal and pathological renal function were obtained from archived studies and distributed to hospitals in the UK. Hospitals were asked to measure five parameters: relative function, renogram time-to-peak (left and right), and whole kidney mean transit time (left and right). Details of methodology, software used and operator experience were requested. This allowed the influence of operational factors on variations in reported values to be examined. A total of 180 responses from 81 hospitals were received. Values reported for the parameters, together with other details supplied, were entered into Excel and SPSS for statistical analysis. Histograms representing the distribution of values were produced for each parameter. The largest variations were found for mean transit time and occasionally for time-to-peak. The effect of factors was assessed using nonparametric statistical tests applied independently to each renogram. For all the parameters, the hospital, UK region, supplier, computer and software version influenced variations in the reported values. Algorithm and site of background region were influencing factors for relative function, the background subtraction method influenced time-to-peak, and curve smoothing influenced mean transit time.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11388579     DOI: 10.1097/00006231-200105000-00015

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Development and prospective evaluation of an automated software system for quality control of quantitative 99mTc-MAG3 renal studies.

Authors:  Russell D Folks; Ernest V Garcia; Andrew T Taylor
Journal:  J Nucl Med Technol       Date:  2007-03

2.  Determination of split renal function by 3D reconstruction of CT angiograms: a comparison with gamma camera renography.

Authors:  Adam L Summerlin; Mark E Lockhart; Andrew M Strang; Peter N Kolettis; Naomi S Fineberg; J Kevin Smith
Journal:  AJR Am J Roentgenol       Date:  2008-11       Impact factor: 3.959

3.  Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse.

Authors:  Michel Destine; François-Xavier Hanin; Isabelle Mathieu; Bernard Willemart; Alain Seret
Journal:  Mol Imaging Radionucl Ther       Date:  2022-02-02
  3 in total