Clinical relevance of loss of atrial sensing in patients with single lead VDD pacemakers.

C M Van Campen1, C C De Cock, J Huijgens, C A Visser.   

Abstract

During single lead VDD pacing, loss of atrial sensing is reported to be 2%-11% of patients in the literature. The impact on quality-of-life and exercise duration has never been established. This study tried to assess the clinical relevance of loss of atrial sensing in patients with single lead VDD pacemakers. Twenty-one patients with total AV block were studied 3 months after single lead VDD pacemaker implantation. During a 6-minute walk test, atrial undersensing was verified and adjusted to achieve undersensing in < 5% (group 1), 5%-10% (group 2), and > 10% (group 3). Patients were allocated to each group in a randomized double blind crossover design. At the end of each 2-month study period all patients underwent symptom limited treadmill exercise testing. Subjective assessment of exercise difficulty was made using the Borg score, and quality-of-life assessment was performed using the Health Status Questionnaire. Exercise duration significantly decreased in group 3 (228 +/- 50 s) as compared to group 1 (257 +/- 42 s) and group 2 (250 +/- 46 sec) with an increase in the Borg score. Quality-of-life was decreased for three subscales in group 3 as compared to group 1 and group 2. In conclusion, atrial undersensing of > 10% in patients with single lead VDD pacing was associated with a decrease in exercise duration and increase in the subjective severity score, in addition to a decrease in quality-of-life. Atrial undersensing of < 10% did not effect exercise test results or quality-of-life. Since all studies reported intact atrioventricular synchrony in > or = 90% of patients, loss of atrial sensing is of limited clinical importance in these patients.

Entities:  

Mesh:

Year:  2001        PMID: 11388099     DOI: 10.1046/j.1460-9592.2001.00806.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  The impact of the distance between the atrial electrode and the atrial wall on atrial undersensing in patients with VDD pacemakers: long-term follow-up.

Authors:  Timucin Altin; Muharrem Guldal; Basar Candemir; Cegerhun Polat; Aydan O Ozdemir; Cansin Tulunay; Cagdas Ozdol; Omer Akyurek; Remzi Karaoguz; Cetin Erol
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

2.  Optimizing mechanically sensed atrial tracking in patients with atrioventricular-synchronous leadless pacemakers: A single-center experience.

Authors:  Kelly Arps; Jonathan P Piccini; Rebecca Yapejian; Rhonda Leguire; Brenda Smith; Sana M Al-Khatib; Tristram D Bahnson; James P Daubert; Donald D Hegland; Kevin P Jackson; Larry R Jackson; Robert K Lewis; Sean D Pokorney; Albert Y Sun; Kevin L Thomas; Camille Frazier-Mills
Journal:  Heart Rhythm O2       Date:  2021-08-23

Review 3.  The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis.

Authors:  Xuanming Pung; Daniel Zhihao Hong; Tzyy Yeou Ho; Xiayan Shen; Pei Ting Tan; Colin Yeo; Vern Hsen Tan
Journal:  J Arrhythm       Date:  2022-01-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.