Literature DB >> 11382079

A three-dimensional finite element model from computed tomography data: a semi-automated method.

P M Cattaneo1, M Dalstra, L H Frich.   

Abstract

Three-dimensional finite element analysis is one of the best ways to assess stress and strain distributions in complex bone structures. However, accuracy in the results may be achieved only when accurate input information is given. A semi-automated method to generate a finite element (FE) model using data retrieved from computed tomography (CT) was developed. Due to its complex and irregular shape, the glenoid part of a left embalmed scapula bone was chosen as working material. CT data were retrieved using a standard clinical CT scanner (Siemens Somatom Plus 2, Siemens AG, Germany). This was done to produce a method that could later be utilized to generate a patient-specific FE model. Different methods of converting Hounsfield unit (HU) values to apparent densities and subsequently to Young's moduli were tested. All the models obtained were loaded using three-dimensional loading conditions taken from literature, corresponding to an arm abduction of 90 degrees. Additional models with different amounts of elements were generated to verify convergence. Direct comparison between the models showed that the best method to convert HU values directly to apparent densities was to use different equations for cancellous and cortical bone. In this study, a reliable method of determining both geometrical data and bone properties from patient CT scans for the semi-automated generation of an FE model is presented.

Entities:  

Mesh:

Year:  2001        PMID: 11382079     DOI: 10.1243/0954411011533760

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  12 in total

1.  Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems.

Authors:  Aki Hasegawa; Akikazu Shinya; Lippo V J Lassila; Daiichiro Yokoyama; Yuji Nakasone; Pekka K Vallittu; Akiyoshi Shinya
Journal:  Odontology       Date:  2012-06-23       Impact factor: 2.634

Review 2.  Current progress in patient-specific modeling.

Authors:  Maxwell Lewis Neal; Roy Kerckhoffs
Journal:  Brief Bioinform       Date:  2009-12-02       Impact factor: 11.622

3.  Computational modeling for bedside application.

Authors:  Roy C P Kerckhoffs; Sanjiv M Narayan; Jeffrey H Omens; Lawrence J Mulligan; Andrew D McCulloch
Journal:  Heart Fail Clin       Date:  2008-07       Impact factor: 3.179

4.  Less than full circumferential fusion of a tibial nonunion is sufficient to achieve mechanically valid fusion--proof of concept using a finite element modeling approach.

Authors:  Thorsten Tjardes; Michael Roland; Robin Otchwemah; Tim Dahmen; Stefan Diebels; Bertil Bouillon
Journal:  BMC Musculoskelet Disord       Date:  2014-12-15       Impact factor: 2.362

5.  Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis.

Authors:  Zhang Xing; Ling Song Chen; Wei Peng; Ling Jian Chen
Journal:  J Craniofac Surg       Date:  2017-03       Impact factor: 1.046

6.  Interlaboratory comparison of femur surface reconstruction from CT data compared to reference optical 3D scan.

Authors:  Ehsan Soodmand; Daniel Kluess; Patrick A Varady; Robert Cichon; Michael Schwarze; Dominic Gehweiler; Frank Niemeyer; Dieter Pahr; Matthias Woiczinski
Journal:  Biomed Eng Online       Date:  2018-03-02       Impact factor: 2.819

7.  High-Biofidelity Biomodel Generated from Three-Dimensional Imaging (Cone-Beam Computed Tomography): A Methodological Proposal.

Authors:  Rosa Alicia Hernández-Vázquez; Guillermo Urriolagoitia-Sosa; Rodrigo Arturo Marquet-Rivera; Beatriz Romero-Ángeles; Octavio Alejandro Mastache-Miranda; Juan Alejandro Vázquez-Feijoo; Guillermo Urriolagoitia-Calderón
Journal:  Comput Math Methods Med       Date:  2020-01-28       Impact factor: 2.238

8.  Effect of RSA glenoid baseplate central fixation on micromotion and bone stress.

Authors:  Nicolas Bonnevialle; Laurent Geais; Jacobus Hendrik Müller; Julien Berhouet
Journal:  JSES Int       Date:  2020-08-01

9.  Correlation between the bone mineral density and stress on femur around a Duetto SI stem.

Authors:  Rina Sakai; Takeaki Yamamoto; Katsufumi Uchiyama; Kentaro Uchida; Masaki Nakao; Kiyoshi Mabuchi
Journal:  ScientificWorldJournal       Date:  2014-06-26

10.  Application of multidimensional interpolation on nonhomogeneous cancellous bone.

Authors:  Sikai Liu; Sheng Li; Ning Wei; Wenli Chang; Pan Hu; Xiaodong Cheng; Ling Wang; Wei Chen
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

View more