Literature DB >> 11380840

Ultrasound dilution evaluation of pediatric hemodialysis vascular access.

S L Goldstein1, A Allsteadt.   

Abstract

BACKGROUND: Hemodialysis access thrombosis is a significant cause of morbidity for hemodialysis patients and results from decreased access flow caused by venous outflow tract stenosis. Ultrasound dilution (UD) is a practical, noninvasive, and reliable indicator of access flow and is effective in predicting venous stenosis in adult patients receiving hemodialysis.
METHODS: The current study is the first to our knowledge to evaluate the accuracy of UD in predicting hemodialysis access stenosis in a pediatric hemodialysis population. Thirteen pediatric patients receiving hemodialysis via permanent access (4 AVF and 9 AVG) received 73 UD measurements over three months.
RESULTS: Mean raw access flow (QA) was 720 +/- 428 mL/min, and mean corrected access flow (QAcorr) was 886 +/- 537 mL/min/1.73 m(2). QAcorr was significantly lower in accesses with stenosis (401 +/- 176 mL/min/1.73 m(2)) versus accesses without stenosis (1158 +/- 330 mL/min/1.73 m(2), P < 0.0001). Unlike flow values reported by raw QA, there was no overlap in flow values reported by QAcorr in accesses with stenosis (174 to 579 mL/min/1.73 m(2)) versus accesses without stenosis (709 to 1711 mL/min/1.73 m(2)). Two patients with an AVG who had QAcorr less than 600 mL/min/1.73 m(2) developed an access thrombosis within one week after UD measurement. No patients with QAcorr greater than 700 mL/min/1.73 m(2) developed access thrombosis in the 30 days following UD measurement.
CONCLUSIONS: : The current study supports the use of monthly UD measurement to prevent access thrombosis in children receiving hemodialysis.

Entities:  

Mesh:

Year:  2001        PMID: 11380840     DOI: 10.1046/j.1523-1755.2001.00753.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  3 in total

Review 1.  Monitoring and Surveillance of Hemodialysis Access.

Authors:  Nischal Koirala; Evamaria Anvari; Gordon McLennan
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

2.  Ultrasound dilution and thermodilution versus color Doppler ultrasound for arteriovenous fistula assessment in children on hemodialysis.

Authors:  Vasiliki Karava; Theresa Kwon; Gilbert Franco; Deschenes Georges; Marie-Alice Macher; Julien Hogan
Journal:  Pediatr Nephrol       Date:  2019-07-19       Impact factor: 3.714

3.  Salvage of a radiocephalic fistula by the palmar arch.

Authors:  Noël Knops; Erik Beek
Journal:  NDT Plus       Date:  2008-08-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.