Literature DB >> 11377904

Glistenings in the AcrySof intraocular lens: pilot study.

G Christiansen1, F J Durcan, R J Olson, K Christiansen.   

Abstract

PURPOSE: To evaluate the prevalence, severity, and visual significance of glistenings seen in the AcrySof intraocular lens (IOL) and determine whether a large in-depth study of this lens is warranted.
SETTING: John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
METHODS: Patients who had the AcrySof IOL implanted at 1 institution over the past 4 years were serially selected. Forty-two eyes that had phacoemulsification with implantation of the AcrySof IOL were evaluated. The examination consisted of visual acuity, glare, contrast sensitivity, and dilated fundus and dilated slitlamp evaluations. Glistenings in the IOL were graded at the slitlamp from trace to 4+.
RESULTS: All 42 IOLs had some degree of lenticular glistenings. The glistenings were graded as trace in 27 IOLs (64%), 1+ in 5 (12%), 2+ in 5 (12%), 3+ in 3 (7%), and 4+ in 2 (5%). The Snellen acuity in eyes with severe glistenings (> or = 2+) was one-half line lower than in eyes with mild glistenings (+) (P =.01). In all eyes, the Brightness Acuity Tester score was a little more than one-half line lower than the Snellen acuity, and the difference was 1 full line in eyes with glistenings graded above 2+. Fourteen of 15 IOLs (93%) with glistenings graded greater than trace had been in the eye for more than 1 year. There was no evidence that contrast sensitivity was affected by the glistenings.
CONCLUSIONS: Glistenings occurred frequently in AcrySof IOLs, with most cases mild. A larger study of this lens is needed to determine whether severe presentations affect visual function and to understand how glistenings change over time.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11377904     DOI: 10.1016/s0886-3350(00)00700-8

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  20 in total

1.  Preoperative opacification of acrylic intraocular lenses in storage.

Authors:  C M Pratt; S Barton; E McGonigle; M Kishi; P J S Foot
Journal:  J Mater Sci Mater Med       Date:  2007-04       Impact factor: 3.896

2.  Effects of glistenings in intraocular lenses.

Authors:  Marrie van der Mooren; Luuk Franssen; Patricia Piers
Journal:  Biomed Opt Express       Date:  2013-07-11       Impact factor: 3.732

3.  Analysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.

Authors:  Lei Xi; Yi Liu; Feng Zhao; Chuan Chen; Bing Cheng
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

4.  Evolution of visual performance in 70 eyes implanted with the Tecnis(®) ZMB00 multifocal intraocular lens.

Authors:  Carlos Palomino Bautista; David Carmona González; Alfredo Castillo Gómez
Journal:  Clin Ophthalmol       Date:  2012-03-21

5.  Glistenings in hydrophobic acrylic intraocular lenses do affect visual function.

Authors:  George Hh Beiko; Andrzej Grzybowski
Journal:  Clin Ophthalmol       Date:  2013-11-27

Review 6.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

7.  Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).

Authors:  Mark Packer; Luther Fry; Kevin T Lavery; Robert Lehmann; James McDonald; Louis Nichamin; Brian Bearie; Jon Hayashida; Griffith E Altmann; Omid Khodai
Journal:  Clin Ophthalmol       Date:  2013-09-24

8.  Safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (enVista®) - results of a European and Asian-Pacific study.

Authors:  Peter Heiner; Edoardo Ligabue; Alex Fan; Dennis Lam
Journal:  Clin Ophthalmol       Date:  2014-03-27

Review 9.  Clinical properties of a novel, glistening-free, single-piece, hydrophobic acrylic IOL.

Authors:  Mark Packer; Mohan Rajan; Edoardo Ligabue; Peter Heiner
Journal:  Clin Ophthalmol       Date:  2014-02-21

10.  Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses.

Authors:  Yunhai Dai; Yusen Huang; Ting Liu; Lixin Xie
Journal:  Indian J Ophthalmol       Date:  2014-06       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.