Literature DB >> 11374772

Inflammatory response after implantation of a left ventricular assist device: comparison between the axial flow MicroMed DeBakey VAD and the pulsatile Novacor device.

M Loebe1, A Koster, S Sänger, E V Potapov, H Kuppe, G P Noon, R Hetzer.   

Abstract

The implantation of a ventricular assist device (VAD) is associated with a stimulation of the inflammatory system. We compared changes in the inflammatory response after implantation of a pulsatile Novacor left (L) VAD and the axial flow MicroMed DeBakey VAD. Six consecutive patients after implantation of a Novacor LVAD (NC) and six patients after implantation of a MicroMed DeBakey VAD (MD) were included in the investigation. Patients received LVADs for medically non treatable end-stage heart failure. Tumor necrosis factor alpha (TNF), C3a, C5a, interleukin 6 (IL-6), and neutrophil elastase were measured twice a week over a period of 3 months after implantation of the device. All tests were performed with an enzyme-linked immunosorbent assay. There was no significant difference in the clinical course of the two groups. All inflammatory parameters were elevated in both groups during the entire period of the investigation. There was no difference in TNF, polynuclear leukocyte elastase, or C3a levels between the two groups; however, IL-6 (NC: 23.6+/-37.6 pg/ml vs. MD: 63+/-114 pg/ml, p < 0.001) and C5a (NC: 708+/-352 microg/L vs. MD: 1,745+/-1,305 microg/L, p < 0.001) were increased significantly more in patients following implantation of the axial flow MicroMed DeBakey VAD. Compared with the pulsatile Novacor device, the implantation of the axial flow MicroMed DeBakey LVAD seems to be associated with an increased stimulation of one part of the inflammatory system. Further investigations are necessary for evaluation of the pathophysiologic mechanism and clinical implications of these findings.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11374772     DOI: 10.1097/00002480-200105000-00023

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  13 in total

Review 1.  Reverse cardiac remodeling enabled by mechanical unloading of the left ventricle.

Authors:  Konstantinos G Malliaras; John V Terrovitis; Stavros G Drakos; John N Nanas
Journal:  J Cardiovasc Transl Res       Date:  2008-09-30       Impact factor: 4.132

2.  Bridge to recovery: understanding the disconnect between clinical and biological outcomes.

Authors:  Stavros G Drakos; Abdallah G Kfoury; Josef Stehlik; Craig H Selzman; Bruce B Reid; John V Terrovitis; John N Nanas; Dean Y Li
Journal:  Circulation       Date:  2012-07-10       Impact factor: 29.690

3.  Optimum control of the Hemopump as a left-ventricular assist device.

Authors:  P He; J Bai; D D Xia
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

4.  Clinical outcomes with use of erythropoiesis stimulating agents in patients with the HeartMate II left ventricular assist device.

Authors:  Michael E Nassif; Jayendrakumar S Patel; Jerrica E Shuster; David S Raymer; Ronald Jackups; Eric Novak; Brian F Gage; Sunil Prasad; Scott C Silvestry; Gregory A Ewald; Shane J LaRue
Journal:  JACC Heart Fail       Date:  2015-02       Impact factor: 12.035

5.  Complement anaphylatoxin C3a as a novel independent prognostic marker in heart failure.

Authors:  Tímea Gombos; Zsolt Förhécz; Zoltán Pozsonyi; Gábor Széplaki; Jan Kunde; George Füst; Lívia Jánoskuti; István Karádi; Zoltán Prohászka
Journal:  Clin Res Cardiol       Date:  2012-02-29       Impact factor: 5.460

Review 6.  Left ventricular assist device unloading effects on myocardial structure and function: current status of the field and call for action.

Authors:  Stavros G Drakos; Abdallah G Kfoury; Craig H Selzman; Divya Ratan Verma; John N Nanas; Dean Y Li; Josef Stehlik
Journal:  Curr Opin Cardiol       Date:  2011-05       Impact factor: 2.161

7.  Change in myocardial oxygen consumption employing continuous-flow LVAD with cardiac beat synchronizing system, in acute ischemic heart failure models.

Authors:  Akihide Umeki; Takashi Nishimura; Yoshiaki Takewa; Masahiko Ando; Mamoru Arakawa; Yuichiro Kishimoto; Tomonori Tsukiya; Toshihide Mizuno; Shunei Kyo; Minoru Ono; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-17       Impact factor: 1.731

Review 8.  Management of allosensitized cardiac transplant candidates.

Authors:  Mauricio Velez; Maryl R Johnson
Journal:  Transplant Rev (Orlando)       Date:  2009-10       Impact factor: 3.943

9.  Living Without a Pulse: The Vascular Implications of Continuous-Flow Left Ventricular Assist Devices.

Authors:  Suneet N Purohit; William K Cornwell; Jay D Pal; JoAnn Lindenfeld; Amrut V Ambardekar
Journal:  Circ Heart Fail       Date:  2018-06       Impact factor: 8.790

10.  Temporal leukocyte numbers and granulocyte activation in pulsatile and rotary ventricular assist device patients.

Authors:  Joshua R Woolley; Jeffrey J Teuteberg; Christian A Bermudez; Jay K Bhama; Kathleen L Lockard; Robert L Kormos; William R Wagner
Journal:  Artif Organs       Date:  2013-10-29       Impact factor: 3.094

View more