Transcranial detection of microembolic signals in patients with a novel nonpulsatile implantable LVAD.

E V Potapov1, B A Nasseri, M Loebe, M Kukucka, A Koster, H Kuppe, G P Noon, M E DeBakey, R Hetzer.   

Abstract

Mechanical ventricular assist devices (VAD) have become an accepted therapy for the support of patients in severe heart failure. With the devices presently available, the incidence of thromboembolic complications is high. Since November 1998, we have used the DeBakey VAD (MicroMed, Inc., Woodlands, TX). To detect the effect of this VAD on the appearance of microthrombi or bubbles from cavitation, we measured Microembolic Signals (MES) with transcranial Doppler in patients after the implantation of the DeBakey VAD. Transcranial Doppler studies were performed with the MULTI-DOP X4 device with two 2 MHz probes (for the left and right middle cranial arteries [MCA]) in five patients preoperatively and during 10 weeks after VAD implantation. Both MCAs were monitored simultaneously for 60 minutes in 10 sessions in each patient. The detection and analysis of MES was performed in accordance with the technique and criteria described by the international consensus group. No MES were noted during the study period in four patients. In one patient with preoperatively noted MES the prevalence of MES postoperatively was 50%. The high speed rotating impeller of the DeBakey VAD did not produce any detectable microthrombi or bubbles from cavitation effects.

Entities:  

Mesh:

Year:  2001        PMID: 11374767     DOI: 10.1097/00002480-200105000-00018

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Assessing Cerebrovascular Hemodynamics Using Transcranial Doppler in Patients with Mechanical Circulatory Support Devices.

Authors:  Kara R Melmed; Konrad H Schlick; Brenda Rinsky; Oana M Dumitrascu; Oksana Volod; Mani Nezhad; Matthew M Padrick; Carmelita Runyan; Francisco A Arabia; Jaime D Moriguchi; Patrick D Lyden; Shlee S Song
Journal:  J Neuroimaging       Date:  2020-02-10       Impact factor: 2.486

2.  Evaluation of micro-emboli in a patient with ventricular assist device support with hemolysis.

Authors:  Osamu Seguchi; Kozue Saito; Kazuki Fukuma; Keiko Shimamoto; Takuma Sato; Seiko Nakajima; Haruki Sunami; Kensuke Kuroda; Takamasa Sato; Takuya Watanabe; Hiroki Hata; Masanobu Yanase; Tomoyuki Fujita; Junjiro Kobayashi; Kazuyuki Nagatsuka; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2015-03-22       Impact factor: 1.731

3.  Frequency analysis of high-intensity transient signals of transcranial Doppler ultrasound in patients supported with a left ventricular assist device.

Authors:  Koichi Sato; Kazuhiko Hanzawa; Takeshi Okamoto; Shunei Kyo; Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2008-12-17       Impact factor: 1.731

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.