Literature DB >> 11374461

Staphylococcus aureus biofilm formation on different gentamicin-loaded polymethylmethacrylate bone cements.

H van de Belt1, D Neut, W Schenk, J R van Horn, H C van Der Mei, H J Busscher.   

Abstract

In this in vitro study, the formation of a Staphylococcus aureus biofilm on six gentamicin-loaded bone cements (CMW1, CMW3, CMW Endurance, CMW2000, Palacos, and Palamed) was determined in a modified Robbins device over a 3 days time span and related with previously (Van de Belt et al., Biomaterials 21 (2000) 1981) measured kinetics of antibiotic release by these cement brands. The influence of gentamicin release on biofilm formation was quantified by expressing the number of colony-forming units on gentamicin-loaded cement relative to the number of viable organisms on unloaded cement of the same brand. Biofilms formed on all gentamicin-loaded cements, despite the release of antibiotics, followed a consistent pattern in time with a maximum number of colony-forming units per unit cement area found between 24 and 30 h after inoculation. None of the gentamicin-loaded cements showed a reduction in biofilm formation relative to unloaded cements within 6 h after inoculation, whereas only gentamicin-loaded CMW1 and Palacos reduced biofilm formation 24 h after inoculation. Alternatively, CMW Endurance, CMW2000, and Palamed did not exhibit any initial reductions in biofilm formation, but effects started after 72, 48, and 72 h, respectively. Biofilm reduction by gentamicin-loaded CMW3 lasted the longest from 24 to 72 h. Interestingly, each cement seemed to have a different "window-of-effectiveness" with regard to reduction in biofilm formation that did not relate with the gentamicin-release kinetics. Summarising, this study demonstrates that although gentamicin loading of bone cements yields reductions in biofilm formation, S. aureus is able to grow on gentamicin-loaded bone cements.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11374461     DOI: 10.1016/s0142-9612(00)00313-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  39 in total

1.  Strength of antimicrobial bone cement decreases with increased poragen fraction.

Authors:  Matt Nugent; Alex McLaren; Brent Vernon; Ryan McLemore
Journal:  Clin Orthop Relat Res       Date:  2010-08       Impact factor: 4.176

2.  A preliminary study of the release of quaternary ammonium antimicrobial compounds from acrylic bone cement.

Authors:  Manojgna Mathey; Vijaya Surana; Mark Edwards; John W Nicholson
Journal:  J Mater Sci Mater Med       Date:  2009-03-04       Impact factor: 3.896

3.  Improved detection of biofilm-formative bacteria by vortexing and sonication: a pilot study.

Authors:  Hideo Kobayashi; Margret Oethinger; Marion J Tuohy; Gary W Procop; Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2008-11-07       Impact factor: 4.176

4.  Mixing method affects elution and strength of high-dose ALBC: a pilot study.

Authors:  Ryan Miller; Alex McLaren; Christine Leon; Ryan McLemore
Journal:  Clin Orthop Relat Res       Date:  2012-10       Impact factor: 4.176

5.  Prophylactic use of antibiotic-loaded bone cement in primary total knee replacement.

Authors:  Pietro Randelli; Francesco R Evola; Paolo Cabitza; Luca Polli; Matteo Denti; Luca Vaienti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-01       Impact factor: 4.342

6.  CORR Insights®: Local gentamicin delivery from resorbable viscous hydrogels is therapeutically effective.

Authors:  Jessica Amber Jennings
Journal:  Clin Orthop Relat Res       Date:  2014-10-10       Impact factor: 4.176

Review 7.  [Treatment of periprosthetic infections].

Authors:  L Renner; C Perka; A Trampuz; N Renz
Journal:  Chirurg       Date:  2016-10       Impact factor: 0.955

Review 8.  Antibiotic-loaded Bone Cement as Prophylaxis in Total Joint Replacement.

Authors:  Javier Martínez-Moreno; Virginia Merino; Amparo Nácher; José Luis Rodrigo; Mónica Climente; Matilde Merino-Sanjuán
Journal:  Orthop Surg       Date:  2017-11       Impact factor: 2.071

9.  Inhibition of Staphylococcus epidermidis biofilms using polymerizable vancomycin derivatives.

Authors:  McKinley C Lawson; Kevin C Hoth; Cole A Deforest; Christopher N Bowman; Kristi S Anseth
Journal:  Clin Orthop Relat Res       Date:  2010-08       Impact factor: 4.176

10.  In Vivo Efficacy of a "Smart" Antimicrobial Implant Coating.

Authors:  Alexandra I Stavrakis; Suwei Zhu; Vishal Hegde; Amanda H Loftin; Alyssa G Ashbaugh; Jared A Niska; Lloyd S Miller; Tatiana Segura; Nicholas M Bernthal
Journal:  J Bone Joint Surg Am       Date:  2016-07-20       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.