Literature DB >> 11359336

Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair.

I V Mohan1, R J Laheij, P L Harris.   

Abstract

OBJECTIVES: the aim of this study was to assess the relationship between patient factors, the anatomy of the proximal aneurysm neck; the type of endovascular graft; and the consequences of graft/neck size mismatch and the occurrence of proximal endoleak. Design multicentre clinical study. MATERIALS: of a total of 2194 patients, 2146 underwent successful endovascular repair of infra-renal abdominal aortic aneurysms (AAA).
METHODS: endoleaks were identified by radiological imaging immediately after completion of the procedure as per study protocols. Clinical and anatomical features of AAA in patients with endoleak were compared to patients without endoleak and data were analysed using the Chi-square test. A multivariate logistic regression model was constructed by selecting variables found to be significantly associated with complications in a univariate analysis.
RESULTS: intra-operative endoleak was observed in 16.7% overall, and 3.3% were noted to have proximal endoleak. Aneurysm size larger than 60 mm (p =0.004), ex-smokers ( p =0.005) and age over 75 years ( p =0.01) were independently associated with endoleak of all types. Univariate and multivariate analysis revealed correlation between proximal endoleak and (i) diameter of the aneurysm neck-proximal (D2a), middle (D2b), distal (D2c), at all levels (p <0.005); (ii) proximal aortic neck length ( p =0.0001); (iii) aortic device diameter ( p =0.0024). No correlation was identified for angulation and form of the aortic neck. A model of the frequency of proximal endoleak, in relation to the ratio of the aortic device diameter to the distal aortic neck diameter, revealed that endoleak decreased when the aortic device diameter became oversized by more than 10% and confidence intervals remained tight for up to and over 20% oversize. Copyright 2001 Harcourt Publishers Limited.

Entities:  

Mesh:

Year:  2001        PMID: 11359336     DOI: 10.1053/ejvs.2000.1341

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  14 in total

1.  Aortic-neck dilation after endovascular abdominal aortic aneurysm repair (EVAR): can it be predicted?

Authors:  R Iezzi; M Santoro; G Di Natale; F Pirro; R Dattesi; M Nestola; F Snider; L Bonomo
Journal:  Radiol Med       Date:  2011-11-17       Impact factor: 3.469

2.  Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b.

Authors:  Tim F Weber; Maria-Katharina Ganten; Dittmar Böckler; Philipp Geisbüsch; Annette Kopp-Schneider; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Eur Radiol       Date:  2008-07-22       Impact factor: 5.315

3.  A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta.

Authors:  S K Lam; George S K Fung; Stephen W K Cheng; K W Chow
Journal:  Med Biol Eng Comput       Date:  2008-07-11       Impact factor: 2.602

4.  Management of Immediate Post-Endovascular Aortic Aneurysm Repair Type Ia Endoleaks and Late Outcomes.

Authors:  Ali F AbuRahma; Stephen M Hass; Zachary T AbuRahma; Michael Yacoub; Albeir Y Mousa; Shadi Abu-Halimah; L Scott Dean; Patrick A Stone
Journal:  J Am Coll Surg       Date:  2016-12-23       Impact factor: 6.113

5.  Feasibility of endovascular abdominal aortic aneurysm repair outside of the instructions for use and morphological changes at 3 years after the procedure.

Authors:  Katsuyuki Hoshina; Takuya Hashimoto; Masaaki Kato; Nobukazu Ohkubo; Kunihiro Shigematsu; Tetsuro Miyata
Journal:  Ann Vasc Dis       Date:  2014-02-28

6.  Role of graft oversizing in the fixation strength of barbed endovascular grafts.

Authors:  Jarin A Kratzberg; Jafar Golzarian; Madhavan L Raghavan
Journal:  J Vasc Surg       Date:  2009-06       Impact factor: 4.268

Review 7.  Advanced Endovascular Approaches in the Management of Challenging Proximal Aortic Neck Anatomy: Traditional Endografts and the Snorkel Technique.

Authors:  Jon G Quatromoni; Ksenia Orlova; Paul J Foley
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

8.  Are abdominal aortic aneurysms with hostile neck really unsuitable for EVAR? Our experience.

Authors:  Paolo Cerini; Giuseppe Guzzardi; Ignazio Divenuto; Giuseppe Parziale; Piero Brustia; Alessandro Carriero; Rita Fossaceca
Journal:  Radiol Med       Date:  2016-02-04       Impact factor: 3.469

9.  Endoleak following endovascular abdominal aortic aneurysm repair: implications for duration of screening.

Authors:  Matthew A Corriere; Irene D Feurer; Stacey Y Becker; Jeffery B Dattilo; Marc A Passman; Raul J Guzman; Thomas C Naslund
Journal:  Ann Surg       Date:  2004-06       Impact factor: 12.969

Review 10.  Fenestrated and Chimney Technique for Juxtarenal Aortic Aneurysm: A Systematic Review and Pooled Data Analysis.

Authors:  Yue Li; Zhongzhou Hu; Chujie Bai; Jie Liu; Tao Zhang; Yangyang Ge; Shaoliang Luan; Wei Guo
Journal:  Sci Rep       Date:  2016-02-12       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.