On cutting torque measurements during implant placement: a 3-year clinical prospective study.

B Friberg1, L Sennerby, K Gröndahl, C Bergström, T Bäck, U Lekholm.   

Abstract

BACKGROUND: Evaluation of jaw bone quality at implant placement is mainly based on preoperative radiographic assessments and subjective hand registrations during implant site preparation. An objective technique with cutting torque measurements has been introduced, presenting an objective bone quality or bone hardness value of individual implant sites.
PURPOSE: The purpose of this study was to evaluate cutting torque measurements during implant placement and to compare these values in different regions in mandibles and maxillae. The objective was to identify implants at risk for failing at implant placement.
MATERIAL AND METHODS: Cutting torque measurements were performed during placement of Mk II self-tapping implants (Brånemark System) in 105 patients, comprising 72 edentulous (40 maxillae) and 34 partially edentulous (22 maxillae) jaws. A total of 523 implants were inserted, of which 420 were of the Mk II design and of which 412 were subjected to cutting torque measurements. Statistical analyses were performed by comparing cutting torque values of maxillae and mandibles and of different jaw regions. Cutting torque values were also correlated with radiographically and clinically assessed bone quality scores. Patients were followed clinically for a minimum of 3 years.
RESULTS: A statistically significant difference in cutting torque values of maxillae and mandibles was seen, although not when comparing anterior and posterior regions within the same jaws or of different jaws. Significant correlations were found between values of cutting torque and bone quality. The majority of failures were seen in bone of medium to high density, whereas implants inserted in bone of poor density presented a better outcome, perhaps due to an adapted surgical protocol and an extended healing period. The overall implant survival rate at 3 years was 95%, and when analyzing different jaw categories, survival rates of 92.0% and 99.4% were seen for edentulous maxillae and mandibles, respectively. The corresponding figures for partially edentulous jaws were 95.4% and 97.6%.
CONCLUSION: It was not possible to identify sites at risk for future implant losses or to determine a lower limit value of cutting torque in order to achieve successful implant integration.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 11359301     DOI: 10.1111/j.1708-8208.1999.tb00095.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

Review 1.  Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-21

2.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

3.  Effects of screw and host factors on insertion torque and pullout strength.

Authors:  Ankit H Shah; Rolf G Behrents; Ki Beom Kim; Hee-Moon Kyung; Peter H Buschang
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

Review 4.  Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review.

Authors:  Rola Muhammed Shadid; Nasrin Rushdi Sadaqah; Sahar Abdo Othman
Journal:  Int J Dent       Date:  2014-07-07

5.  Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep.

Authors:  Michele Stocchero; Yohei Jinno; Marco Toia; Marianne Ahmad; Evaggelia Papia; Satoshi Yamaguchi; Jonas P Becktor
Journal:  J Clin Med       Date:  2019-08-11       Impact factor: 4.241

6.  Use of temporary abutment to assess implant osseointegration before final impression: A case report.

Authors:  Nawaf Labban
Journal:  Clin Case Rep       Date:  2021-12-04

Review 7.  Current trends to measure implant stability.

Authors:  Vasanthi Swami; Vasantha Vijayaraghavan; Vinit Swami
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

8.  Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture.

Authors:  Afsheen Tabassum; Gert J Meijer; Vincent M J I Cuijpers; X Frank Walboomers
Journal:  Saudi Dent J       Date:  2020-03-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.