Transfer of normal 99mTc-ECD brain SPET databases between different gamma cameras.

K Van Laere1, M Koole, J Versijpt, S Vandenberghe, B Brans, Y D'Asseler, O De Winter, A Kalmar, R Dierckx.   

Abstract

A stereotactic, normal perfusion database is imperative for optimal clinical brain single-photon emission tomography (SPET). However, interdepartmental use of normal data necessitates accurate transferability of these data sets. The aim of this study was to investigate transfer of three normal perfusion databases obtained in the same large population of healthy volunteers who underwent sequential scanning using multihead gamma cameras with different resolution. Eighty-nine healthy adults (46 females, 43 males; aged 20-81 years) were thoroughly screened by history, biochemistry, physical and full neurological examination, neuropsychological testing and magnetic resonance imaging. After injection of 925 MBq technetium-99m labelled ethyl cysteinate dimer (ECD) under standard conditions, 101 scans were acquired from all subjects (12 repeat studies) on a triple-head Toshiba GCA-9300A (measured average FWHM 8.1 mm). Ninety-one sequential scans were performed on a dual-head Elscint Helix camera (FWHM 9.6 mm) and 22 subjects also underwent imaging on a triple-head Prism 3000 (FWHM 9.6 mm). Images were transferred to the same processing platform and reconstructed by filtered back-projection with the same Butterworth filter (order 8, cut-off 0.9 cycles/cm) and uniform Sorensen attenuation correction (mu = 0.09). After automated rigid intrasubject registration, all subjects were automatically reoriented to a stereotactic template by a nine-parameter affine transformation. The databases were analysed using 35 predefined volumes of interest (VOIs) with normalisation on total VOI counts. For comparison, the high-resolution data were smoothed with a 3D Gaussian kernel to achieve more similar spatial resolution. Hoffman phantom measurements were conducted on all cameras. Partial volume effects after smoothing varied between -6.5% and 10%, depending on VOI size. Between-camera reproducibility was 2.5% and 2.7% for the Toshiba camera versus the Helix and the Prism database, respectively. The highest reduction in between-camera variability was achieved by resolution adjustment in combination with linear washout correction and a Hoffman phantom-based correction. In conclusion, transfer of normal perfusion data between multihead gamma cameras can be accurately achieved, thereby enabling widespread interdepartmental use, which is likely to have a positive impact on the diagnostic capabilities of clinical brain perfusion SPET.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11357493     DOI: 10.1007/s002590000461

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  6 in total

1.  Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

Authors:  Miho Shidahara; Hiroshi Watabe; Kyeong Min Kim; Takashi Kato; Shoji Kawatsu; Rikio Kato; Kumiko Yoshimura; Hidehiro Iida; Kengo Ito
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-28       Impact factor: 9.236

Review 2.  Stereotactic statistical imaging analysis of the brain using the easy Z-score imaging system for sharing a normal database.

Authors:  Sunao Mizumura; Shin-ichiro Kumita
Journal:  Radiat Med       Date:  2006-08

3.  Quantification of Parkinson's disease-related network expression with ECD SPECT.

Authors:  Thomas Eckert; Koen Van Laere; Chengke Tang; Daniel E Lewis; Christine Edwards; Patrick Santens; David Eidelberg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-11-10       Impact factor: 9.236

4.  Study of childhood onset schizophrenia (COS) using SPECT and neuropsychological assessment.

Authors:  Savita Malhotra; Nitin Gupta; Anish Bhattacharya; Mehak Kapoor
Journal:  Indian J Psychiatry       Date:  2006-10       Impact factor: 1.759

5.  Dopamine transporter SPECT using fast kinetic ligands: 123I-FP-beta-CIT versus 99mTc-TRODAT-1.

Authors:  K Van Laere; L De Ceuninck; R Dom; J Van den Eynden; H Vanbilloen; J Cleynhens; P Dupont; G Bormans; A Verbruggen; L Mortelmans
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-03       Impact factor: 9.236

6.  Automated discrimination between very early Alzheimer disease and controls using an easy Z-score imaging system for multicenter brain perfusion single-photon emission tomography.

Authors:  H Matsuda; S Mizumura; T Nagao; T Ota; T Iizuka; K Nemoto; N Takemura; H Arai; A Homma
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.