Implantation of a dual chamber pacing and sensing single pass defibrillation lead.

R Gradaus1, M Block, A Dorszewski, C Schriever, D Hammel, H H Scheld, M Borggrefe, G Breithardt, D Böcker.   

Abstract

Dual-chamber ICDs are increasingly used to avoid inappropriate shocks due to supraventricular tachycardias. Additionally, many ICD patients will probably benefit from dual chamber pacing. The purpose of this pilot study was to evaluate the intraoperative performance and short-term follow-up of an innovative single pass right ventricular defibrillation lead capable of bipolar sensing and pacing in the right atrium and ventricle. Implantation of this single pass right ventricular defibrillation lead was successful in all 13 patients (age 63 +/- 8 years; LVEF 0.44 +/- 0.16; New York Heart Association [NYHA] 2.4 +/- 0.4, previous open heart surgery in all patients). The operation time was 79 +/- 29 minutes, the fluoroscopy time 4.7 +/- 3.1 minutes. No perioperative complications occurred. The intraoperative atrial sensing was 1.7 +/- 0.5 mV, the atrial pacing threshold product was 0.20 +/- 0.14 V/ms (range 0.03-0.50 V/ms). The defibrillation threshold was 8.8 +/- 2.7 J. At prehospital discharge and at 1-month and 3-month follow-up, atrial sensing was 1.9 +/- 0.9, 2.1 +/- 0.5, and 2.7 +/- 0.6 mV, respectively, (P = NS, P < 0.05, P < 0.05 to implant, respectively), the mean atrial threshold product 0.79, 1.65, and 1.29 V/ms, respectively. In two patients, an intermittent exit block occurred in different body postures. All spontaneous and induced ventricular arrhythmias were detected and terminated appropriately. Thus, in a highly selected patient group, atrial and ventricular sensing and pacing with a single lead is possible under consideration of an atrial pacing dysfunction in 17% of patients.

Entities:  

Mesh:

Year:  2001        PMID: 11341077     DOI: 10.1046/j.1460-9592.2001.00416.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  The Dx-AF study: a prospective, multicenter, randomized controlled trial comparing VDD-ICD to VVI-ICD in detecting sub-clinical atrial fibrillation in defibrillator patients.

Authors:  Mohammed Shurrab; Amir Janmohamed; Jean-François Sarrazin; Felix Ayala-Paredes; Marcio Sturmer; Randall Williams; Satish Toal; Chris Lane; Kevin E Thorpe; Jeff S Healey; Eugene Crystal
Journal:  J Interv Card Electrophysiol       Date:  2017-07-27       Impact factor: 1.900

2.  A new single chamber implantable defibrillator with atrial sensing: a practical demonstration of sensing and ease of implantation.

Authors:  Dietmar Bänsch; Ralph Schneider; Ibrahim Akin; Cristoph A Nienaber
Journal:  J Vis Exp       Date:  2012-02-28       Impact factor: 1.355

Review 3.  Algorithms for better arrhythmia discrimination in implantable cardioverter defibrillators.

Authors:  R Schimpf; C Wolpert; B Lüderitz
Journal:  Curr Cardiol Rep       Date:  2001-11       Impact factor: 2.931

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.