Literature DB >> 11337543

Usefulness of 99mTc-ciprofloxacin (infecton) scan in diagnosis of chronic orthopedic infections: comparative study with 99mTc-HMPAO leukocyte scintigraphy.

K Sonmezoglu1, M Sonmezoglu, M Halac, I Akgün, C Türkmen, C Onsel, B Kanmaz, K Solanki, K E Britton, I Uslu.   

Abstract

UNLABELLED: 99mTc-labeled ciprofloxacin (infecton) has been developed for detecting infectious foci, which localize in high concentrations in living bacteria. Other studies performed with various infections in animals and humans have found that infecton is a promising agent with better specificity for bacterial infections than white blood cell (WBC) scans. In this study, we evaluated the efficacy of infecton scintigraphy for detecting chronic bone and joint infections.
METHODS: Fifty-six sites with suspected bone or joint infection were examined with 99mTc-WBC and infecton scans in 51 patients. Of these patients, 21 had prosthetic implant materials. Biochemical, radiologic, and microbiologic data and clinical outcomes also contributed, along with the results from scintigraphic techniques, in determining the presence or absence of infection. Scintigraphic images were produced at 1 and 4 h after injection of 370-400 MBq infecton or 185-200 MBq 99mTc-hexamethylpropyleneamine oxime (HMPAO)-WBCs. For each patient, there were at least 2 d and at most 7 d between scintigraphic studies.
RESULTS: There were 30 true-positive, 4 false-positive, 20 true-negative, and 2 false-negative results with infecton. With 99mTc-HMPAO-WBCs, the results were 20, 1, 23, and 12, respectively. Values for sensitivity, specificity, and accuracy were 94%, 83%, and 89%, respectively, with the infecton scan and 63%, 96%, and 77%, respectively, with WBC scanning. Differences between the two agents were statistically significant (P < 0.001). Infecton and WBC scan results were in general concordance for 43 of 56 sites (77%). Infecton results for vertebral infections were the most notable findings in this study, despite the limited number of patients with this condition. Infecton scans were positive for hot spots in five of six patients with vertebral osteomyelitis. WBC scans showed photon-deficient areas in four of these same patients and normal distribution in the remaining two patients.
CONCLUSION: Infecton is a useful agent for detecting infectious foci in bones and joints. Moreover, the infecton scan seems to be a more powerful tool in diagnosing vertebral infections than WBC scintigraphy.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11337543

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  24 in total

Review 1.  Prosthetic joint infections: radionuclide state-of-the-art imaging.

Authors:  Filip Gemmel; Hans Van den Wyngaert; Charito Love; M M Welling; Paul Gemmel; Christopher J Palestro
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-02-24       Impact factor: 9.236

Review 2.  Radiotracers used for the scintigraphic detection of infection and inflammation.

Authors:  Chris Tsopelas
Journal:  ScientificWorldJournal       Date:  2015-02-08

3.  Comparative diagnostic accuracy of respective nuclear imaging for suspected fracture-related infection: a systematic review and Bayesian network meta-analysis.

Authors:  Qingyu Zhang; Jinlei Dong; Yelong Shen; Canhua Yun; Dongsheng Zhou; Fanxiao Liu
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-08       Impact factor: 3.067

4.  Joint EANM/ESNR and ESCMID-endorsed consensus document for the diagnosis of spine infection (spondylodiscitis) in adults.

Authors:  Elena Lazzeri; Alessandro Bozzao; Maria Adriana Cataldo; Nicola Petrosillo; Luigi Manfrè; Andrej Trampuz; Alberto Signore; Mario Muto
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-08-09       Impact factor: 9.236

Review 5.  Ciprofloxacin: from infection therapy to molecular imaging.

Authors:  Syed Ali Raza Naqvi; Samina Roohi; Anam Iqbal; Tauqir A Sherazi; Ameer Fawad Zahoor; Muhammad Imran
Journal:  Mol Biol Rep       Date:  2018-07-04       Impact factor: 2.316

Review 6.  Role of modern imaging techniques for diagnosis of infection in the era of 18F-fluorodeoxyglucose positron emission tomography.

Authors:  Rakesh Kumar; Sandip Basu; Drew Torigian; Vivek Anand; Hongming Zhuang; Abass Alavi
Journal:  Clin Microbiol Rev       Date:  2008-01       Impact factor: 26.132

7.  FDG and FDG-labelled leucocyte PET/CT in the imaging of prosthetic joint infection.

Authors:  Sabire Yılmaz Aksoy; Sertac Asa; Meftune Ozhan; Meltem Ocak; M Sait Sager; Melih Engin Erkan; Metin Halac; Levent Kabasakal; Kerim Sönmezoglu; Bedii Kanmaz
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-06       Impact factor: 9.236

8.  Diagnosis and treatment of implant-associated septic arthritis and osteomyelitis.

Authors:  Andrej Trampuz; Werner Zimmerli
Journal:  Curr Infect Dis Rep       Date:  2008-09       Impact factor: 3.725

9.  Tc-99m Ciprofloxacin SPECT of Pulmonary Tuberculosis.

Authors:  Minkyung Lee; Minki Yoon; Kyung Hoon Hwang; Wonsick Choe
Journal:  Nucl Med Mol Imaging       Date:  2010-04-21

10.  99mTc-ciprofloxacin planar and tomographic imaging for the diagnosis of infection in the postoperative spine: experience in 48 patients.

Authors:  Frederic De Winter; Filip Gemmel; Koen Van Laere; Olivier De Winter; Bart Poffijn; Rudi A Dierckx; Christophe Van de Wiele
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.