Literature DB >> 11328769

In vitro evaluation of the risk of developing bacterial resistance to antiseptics and antibiotics used in medical devices.

S M Tambe1, L Sampath, S M Modak.   

Abstract

The risk of development of resistance in Staphylococcus epidermidis to the antibiotics and antiseptics impregnated in central venous catheters was evaluated. The culture was passaged 10-20 times through subinhibitory concentrations of different antimicrobials, singly and in combination, and the MIC of each antimicrobial before and after passage was compared. There was a 10- to 16-fold increase in the MIC of the combination of minocycline and rifampicin, while no significant increase in the MIC of minocycline alone was seen. The MIC of rifampicin was 25,000-fold higher against strains passaged through rifampicin alone (as compared with that for the original strain), while the increase was only 80-fold when it was combined with minocycline for passage. There was no substantial change in susceptibility to the antiseptic chlorhexidine when used alone or in combination with either silver sulphadiazine or triclosan (the MIC of triclosan alone increased eight-fold). In time-kill studies, synergy was observed between chlorhexidine and both triclosan and silver sulphadiazine. Zone of inhibition tests of catheters impregnated with minocycline and rifampicin showed that their activity against rifampicin-resistant strains was lower than that against the susceptible strain. On the other hand, the activity of the antiseptic (chlorhexidine and silver sulphadiazine) catheters against the rifampicin-resistant and -susceptible strains was similar. Although this study indicates that antibiotic catheters may be at a higher risk of being colonized by antibiotic-resistant bacteria, the implications of these results in clinical settings need to be determined.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11328769     DOI: 10.1093/jac/47.5.589

Source DB:  PubMed          Journal:  J Antimicrob Chemother        ISSN: 0305-7453            Impact factor:   5.790


  37 in total

Review 1.  Infections associated with medical devices: pathogenesis, management and prophylaxis.

Authors:  Christof von Eiff; Bernd Jansen; Wolfgang Kohnen; Karsten Becker
Journal:  Drugs       Date:  2005       Impact factor: 9.546

2.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

3.  In vitro interaction between fluconazole and triclosan against clinical isolates of fluconazole-resistant Candida albicans determined by different methods.

Authors:  Lu Yu; Guanghui Ling; Xuming Deng; Jing Jin; Qi Jin; Na Guo
Journal:  Antimicrob Agents Chemother       Date:  2011-05-16       Impact factor: 5.191

Review 4.  Technologic advances in endotracheal tubes for prevention of ventilator-associated pneumonia.

Authors:  Juan F Fernandez; Stephanie M Levine; Marcos I Restrepo
Journal:  Chest       Date:  2012-07       Impact factor: 9.410

5.  Comparison of antimicrobial impregnation with tunneling of long-term central venous catheters: a randomized controlled trial.

Authors:  Rabih O Darouiche; David H Berger; Nancy Khardori; Claudia S Robertson; Matthew J Wall; Michael H Metzler; Seema Shah; Mohammad D Mansouri; Colleen Cerra-Stewart; James Versalovic; Michael J Reardon; Issam I Raad
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

Review 6.  Epidemiologic background of hand hygiene and evaluation of the most important agents for scrubs and rubs.

Authors:  Günter Kampf; Axel Kramer
Journal:  Clin Microbiol Rev       Date:  2004-10       Impact factor: 26.132

7.  Development of resistance of mutans streptococci and Porphyromonas gingivalis to chlorhexidine digluconate and amine fluoride/stannous fluoride-containing mouthrinses, in vitro.

Authors:  Eva M Kulik; Tuomas Waltimo; Roland Weiger; Irene Schweizer; Krystyna Lenkeit; Elisabeth Filipuzzi-Jenny; Clemens Walter
Journal:  Clin Oral Investig       Date:  2014-12-09       Impact factor: 3.573

8.  Guidelines for the prevention of intravascular catheter-related infections: recommendations relevant to interventional radiology for venous catheter placement and maintenance.

Authors:  Donald L Miller; Naomi P O'Grady
Journal:  J Vasc Interv Radiol       Date:  2012-08       Impact factor: 3.464

9.  Assessment of the Potential for Inducing Resistance in Multidrug-Resistant Organisms from Exposure to Minocycline, Rifampin, and Chlorhexidine Used To Treat Intravascular Devices.

Authors:  Joel Rosenblatt; Nylev Vargas-Cruz; Ruth A Reitzel; Issam I Raad
Journal:  Antimicrob Agents Chemother       Date:  2019-04-25       Impact factor: 5.191

10.  Assessment of the in vivo formation of biofilm on external ventricular drainages.

Authors:  P Ramírez; M Gordón; A Soriano; S Gil-Perotin; V Marti; E M Gonzalez-Barbera; M T Sanchez-Aguilar; J A Simal; J Bonastre
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-05-25       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.