Literature DB >> 11324949

Point dose calculations using an analytical pencil beam kernel for IMRT plan checking.

Y Watanabe1.   

Abstract

A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.

Mesh:

Year:  2001        PMID: 11324949     DOI: 10.1088/0031-9155/46/4/309

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

2.  Modulation factors calculated with an EPID-derived MLC fluence model to streamline IMRT/VMAT second checks.

Authors:  Stephen Steciw; Satyapal Rathee; Brad Warkentin
Journal:  J Appl Clin Med Phys       Date:  2013-11-08       Impact factor: 2.102

3.  Independent calculation of dose from a helical TomoTherapy unit.

Authors:  John P Gibbons; Koren Smith; Dennis Cheek; Isaac Rosen
Journal:  J Appl Clin Med Phys       Date:  2009-02-05       Impact factor: 2.102

4.  Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program.

Authors:  J J Haslam; D V Bonta; A E Lujan; C Rash; W Jackson; J C Roeske
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

5.  Commissioning results of an automated treatment planning verification system.

Authors:  Christopher L Nelson; Bryan E Mason; Ronald C Robinson; Kelly D Kisling; Steven M Kirsner
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102