Literature DB >> 11323333

The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patients.

I J Kallmeyer1, C D Collard, J A Fox, S C Body, S K Shernan.   

Abstract

UNLABELLED: Transesophageal echocardiography (TEE) is an invaluable intraoperative diagnostic monitor that is considered to be relatively safe and noninvasive. Insertion and manipulation of the TEE probe, however, may cause oropharyngeal, esophageal, or gastric trauma. We report the incidence of intraoperative TEE-associated complications in a single-center series of 7200 adult cardiac surgical patients. Information related to intraoperative TEE-associated complications was obtained retrospectively from the intraoperative TEE data form, routine postoperative visits, and cardiac surgical morbidity and mortality data. The overall incidences of TEE-associated morbidity and mortality in the study population were 0.2% and 0%, respectively. The most common TEE-associated complication was severe odynophagia, which occurred in 0.1% of the study population. Other complications included dental injury (0.03%), endotracheal tube malpositioning (0.03%), upper gastrointestinal hemorrhage (0.03%), and esophageal perforation (0.01%). TEE probe insertion was unsuccessful or contraindicated in 0.18% and 0.5% of the study population, respectively. These data suggest that intraoperative TEE is a relatively safe diagnostic monitor for the management of cardiac surgical patients. IMPLICATIONS: The overall morbidity (0.2%) and mortality (0%) rates of intraoperative transesophageal echocardiography (TEE) were determined in a retrospective case series of 7200 adult, anesthetized cardiac surgical patients. The most common source of TEE-associated morbidity was odynophagia (0.1%), which resolved with conservative management. These results suggest that TEE is a safe diagnostic tool for the management of cardiac surgical patients.

Entities:  

Mesh:

Year:  2001        PMID: 11323333     DOI: 10.1097/00000539-200105000-00009

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  50 in total

Review 1.  Intraoperative echocardiography in valvular heart disease: an evidence-based appraisal.

Authors:  Hector I Michelena; Martin D Abel; Rakesh M Suri; William K Freeman; Roger L Click; Thoralf M Sundt; Hartzell V Schaff; Maurice Enriquez-Sarano
Journal:  Mayo Clin Proc       Date:  2010-07       Impact factor: 7.616

2.  Hypopharyngeal perforation caused by intraoperative transesophageal echocardiography.

Authors:  Shigeru Toyoda; Shu Inami; Taito Masawa; Ikuko Shibasaki; Yasuyuki Yamada; Hirotsugu Fukuda; Tsukasa Kubo; Masanobu Nakajima; Hiroyuki Kato; Teruo Inoue
Journal:  J Med Ultrason (2001)       Date:  2014-11-26       Impact factor: 1.314

Review 3.  [Perioperative transesophageal echocardiography in non-cardiac surgery. Update].

Authors:  D Wally; C Velik-Salchner
Journal:  Anaesthesist       Date:  2015-09       Impact factor: 1.041

Review 4.  Echocardiographic guidance of transcatheter closure of atrial septal defects: is intracardiac echocardiography better than transesophageal echocardiography?

Authors:  P Koenig; Q L Cao
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

5.  Canadian guidelines for training in adult perioperative transesophageal echocardiography. Recommendations of the Cardiovascular Section of the Canadian Anesthesiologists' Society and the Canadian Society of Echocardiography.

Authors:  François Béïque; Mohamed Ali; Mark Hynes; Scott Mackenzie; André Denault; André Martineau; Charles MacAdams; Cory Sawchuk; Kristine Hirsch; Martin Lampa; Patricia Murphy; Georges Honos; Bradley Munt; Anthony Sanfilippo; Peter Duke
Journal:  Can J Cardiol       Date:  2006-10       Impact factor: 5.223

Review 6.  [Imaging in mitral valve interventions].

Authors:  F Kreidel; H Alessandrini; C Frerker; T Thielsen; U Schäfer; K H Kuck
Journal:  Herz       Date:  2013-08       Impact factor: 1.443

7.  [The heart catheter table is not the operating table : Intraindividual comparison of pulmonary artery pressures].

Authors:  M U Ziegler; H Reinelt
Journal:  Anaesthesist       Date:  2018-04-05       Impact factor: 1.041

8.  A case of anastomosis malposition of the Blalock-Taussig shunt diagnosed using perioperative transesophageal echocardiography monitoring.

Authors:  Tomohiro Yamamoto; Ehrenfried Schindler
Journal:  J Clin Monit Comput       Date:  2013-09-13       Impact factor: 2.502

9.  Gastric bleeding detected by transesophageal echocardiography during cardiopulmonary bypass.

Authors:  Masaki Ito; Shin Kagaya; Takeshi Kitoh; Sohtaro Miyoshi
Journal:  J Anesth       Date:  2010-01-06       Impact factor: 2.078

10.  A systematic approach to performing a comprehensive transesophageal echocardiogram. A call to order.

Authors:  Avinash A Kothavale; Susan B Yeon; Warren J Manning
Journal:  BMC Cardiovasc Disord       Date:  2009-05-13       Impact factor: 2.298

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.