Literature DB >> 11321311

Ultrasensitive detection of CrO4(2-) using a microcantilever sensor.

H F Ji1, T Thundat, R Dabestani, G M Brown, P F Britt, P V Bonnesen.   

Abstract

Microcantilevers modified with a self-assembled monolayer respond sensitively to specific ion concentrations. Here, we report the detection of trace amounts of CrO4(2-) using microcantilevers modified with a self-assembled monolayer of triethyl-12-mercaptododecylammonium bromide. The self-assembled monolayer was prepared on a silicon microcantilever coated with a thin layer of gold on one side. The microcantilever undergoes bending due to sorption of CrO4(2-) ions on the monolayer-modified side. It was found that a concentration of 10(-9) M CrO4(2-) can be detected using this technology in a flow cell. Other anions, such as Cl-, Br-, CO3(2-) (or HCO3-), and SO4(2-), have minimal effect on the deflection of this cantilever. The mechanics of the bending and the chemistry of cantilever modification are discussed.

Entities:  

Year:  2001        PMID: 11321311     DOI: 10.1021/ac0013103

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Microcantilevers modified by specific peptide for selective detection of trimethylamine.

Authors:  Xin Huang; Mingfu Li; Xiaohe Xu; Hongjun Chen; Hai-Feng Ji; Shuifang Zhu
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

2.  Optical determination of Cr(VI) using regenerable, functionalized sol-gel monoliths.

Authors:  Nathan A Carrington; George H Thomas; D Lynn Rodman; David B Beach; Zi-Ling Xue
Journal:  Anal Chim Acta       Date:  2006-08-24       Impact factor: 6.558

3.  Improved surface modification approach for micromechanical biosensors.

Authors:  Hongyan Gao; Koutilya R Buchapudi; Abraham Harms-Smyth; Marvin K Schulte; Xiaohe Xu; Hai-Feng Ji
Journal:  Langmuir       Date:  2007-12-22       Impact factor: 3.882

Review 4.  Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors.

Authors:  Hai-Feng Ji; Benjamin D Armon
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

5.  Electrochemical deposition of sol-gel films for enhanced chromium(VI) determination in aqueous solutions.

Authors:  Nathan A Carrington; Li Yong; Zi-Ling Xue
Journal:  Anal Chim Acta       Date:  2006-05-16       Impact factor: 6.558

6.  A self-sensing piezoelectric microcantilever biosensor for detection of ultrasmall adsorbed masses: theory and experiments.

Authors:  Samira Faegh; Nader Jalili; Srinivas Sridhar
Journal:  Sensors (Basel)       Date:  2013-05-10       Impact factor: 3.576

7.  Detection of feline coronavirus using microcantilever sensors.

Authors:  Sreepriya Velanki; Hai-Feng Ji
Journal:  Meas Sci Technol       Date:  2006-10-05       Impact factor: 2.046

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.