Literature DB >> 11315823

Mini-dose glucagon rescue for hypoglycemia in children with type 1 diabetes.

M W Haymond1, B Schreiner.   

Abstract

OBJECTIVE: Children with type 1 diabetes are frequently difficult to manage during times of gastroenteritis or poor oral intake of carbohydrates because of mild or impending hypoglycemia. The present study describes the effective use of small doses of subcutaneous glucagon in these children. RESEARCH DESIGN AND METHODS: We analyzed 33 episodes of impending or mild hypoglycemia in 28 children (ages 6.6 +/- 0.7 years). All were healthy except for type 1 diabetes and an episode of gastroenteritis. Using a standard U-100 insulin syringe, children ages < or = 2 years received two "units" (20 microg) of glucagon subcutaneously and those ages >2 years received one unit/year of age up to 15 units (150 microg). If the blood glucose did not increase within 30 min, the initial dosage was doubled and given at that time. We used patients' self-glucose monitoring devices, aqueous glucagon, standard insulin syringes, and frequent phone contact with a physician and/or a diabetes nurse educator in this study.
RESULTS: Blood glucose was 3.44 +/- 0.15 mmol/l before and 8.11 +/- 0.72 mmol/l 30 min after glucagon. In 14 children, relative hypoglycemia recurred, requiring retreatment (3.48 +/- 0.18 to 6.94 +/- 0.72 mmol/l). In four children, a third dose was required. The glucagon was well tolerated In 28 of the 33 episodes of impending hypoglycemia, the children remained at home and fully recovered. Five children were taken to their local hospital because of concerns of dehydration or fever, but none for hypoglycemia.
CONCLUSIONS: Mini-dose glucagon rescue, using subcutaneous injections, is effective in managing children with type 1 diabetes during episodes of impending hypoglycemia due to gastroenteritis or poor oral intake of carbohydrate.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11315823     DOI: 10.2337/diacare.24.4.643

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  29 in total

1.  Hypoglycemia prevention via pump attenuation and red-yellow-green "traffic" lights using continuous glucose monitoring and insulin pump data.

Authors:  Colleen S Hughes; Stephen D Patek; Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  Hypoglycemia in type 1 diabetes mellitus.

Authors:  Philip E Cryer
Journal:  Endocrinol Metab Clin North Am       Date:  2010-09       Impact factor: 4.741

Review 3.  Role of Glucagon in Automated Insulin Delivery.

Authors:  Leah M Wilson; Peter G Jacobs; Jessica R Castle
Journal:  Endocrinol Metab Clin North Am       Date:  2019-12-10       Impact factor: 4.741

4.  Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes.

Authors:  P A Bakhtiani; J El Youssef; A K Duell; D L Branigan; P G Jacobs; M R Lasarev; J R Castle; W K Ward
Journal:  J Diabetes Complications       Date:  2014-09-16       Impact factor: 2.852

5.  Development of a highly stable, nonaqueous glucagon formulation for delivery via infusion pump systems.

Authors:  Brett Newswanger; Steve Ammons; Neelima Phadnis; W Kenneth Ward; Jessica Castle; Robert W Campbell; Steven J Prestrelski
Journal:  J Diabetes Sci Technol       Date:  2015-01

6.  Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic Swine.

Authors:  Firas H El-Khatib; John Jiang; Edward R Damiano
Journal:  J Diabetes Sci Technol       Date:  2007-03

7.  Treating severe hypoglycemia: rapid mixing of lyophilized glucagon and diluent at point of care with the Enject GlucaPen.

Authors:  Dick Rylander
Journal:  J Diabetes Sci Technol       Date:  2014-09-02

8.  Comparative Pharmacokinetic/Pharmacodynamic Study of Liquid Stable Glucagon Versus Lyophilized Glucagon in Type 1 Diabetes Subjects.

Authors:  Jessica R Castle; Joseph El Youssef; Deborah Branigan; Brett Newswanger; Poul Strange; Martin Cummins; Leon Shi; Steven Prestrelski
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

9.  Preserved glucose response to low-dose glucagon after exercise in insulin-pump-treated individuals with type 1 diabetes: a randomised crossover study.

Authors:  Isabelle I K Steineck; Ajenthen Ranjan; Signe Schmidt; Trine R Clausen; Jens J Holst; Kirsten Nørgaard
Journal:  Diabetologia       Date:  2019-01-14       Impact factor: 10.122

10.  Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes.

Authors:  Jessica R Castle; Julia M Engle; Joseph El Youssef; Ryan G Massoud; Kevin C J Yuen; Ryland Kagan; W Kenneth Ward
Journal:  Diabetes Care       Date:  2010-03-23       Impact factor: 17.152