"In vivo" determination of hip joint separation and the forces generated due to impact loading conditions.

D A Dennis1, R D Komistek, E J Northcut, J A Ochoa, A Ritchie.   

Abstract

Numerous supporting structures assist in the retention of the femoral head within the acetabulum of the normal hip joint including the capsule, labrum, and ligament of the femoral head (LHF). During total hip arthroplasty (THA), the LHF is often disrupted or degenerative and is surgically removed. In addition, a portion of the remaining supporting structures is transected or resected to facilitate surgical exposure. The present study analyzes the effects of LHF absence and surgical dissection in THA patients. Twenty subjects (5 normal hip joints, 10 nonconstrained THA, and 5 constrained THA) were evaluated using fluoroscopy while performing active hip abduction. All THA subjects were considered clinically successful. Fluoroscopic videos of the normal hips were analyzed using digitization, while those with THA were assessed using a computerized interactive model-fitting technique. The distance between the femoral head and acetabulum was measured to determine if femoral head separation occurred. Error analysis revealed measurements to be accurate within 0.75mm. No separation was observed in normal hips or those subjects implanted with constrained THA, while all 10 (100%) with unconstrained THA demonstrated femoral head separation, averaging 3.3mm (range 1.9-5.2mm). This study has shown that separation of the prosthetic femoral head from the acetabular component can occur. The normal hip joint has surrounding capsuloligamentous structures and a ligament attaching the femoral head to the acetabulum. We hypothesize that these soft tissue supports create a passive, resistant force at the hip, preventing femoral head separation. The absence of these supporting structures after THA may allow increased hip joint forces, which may play a role in premature polyethylene wear or prosthetic loosening.

Entities:  

Mesh:

Year:  2001        PMID: 11311703     DOI: 10.1016/s0021-9290(00)00239-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  Evaluating the accuracy of wear formulae for acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2009-10-10       Impact factor: 2.602

2.  Assessment of the applicability of the Hertzian contact theory to edge-loaded prosthetic hip bearings.

Authors:  Anthony P Sanders; Rebecca M Brannon
Journal:  J Biomech       Date:  2011-10-01       Impact factor: 2.712

3.  Concomitant evolution of wear and squeaking in dual-severity, lubricated wear testing of ceramic-on-ceramic hip prostheses.

Authors:  Anthony Sanders; Ira Tibbitts; Rebecca Brannon
Journal:  J Orthop Res       Date:  2012-02-21       Impact factor: 3.494

4.  Does Femoral Head Translation Vary by Sex and Side in Asymptomatic Hips During a Weightbearing Apprehension Test?

Authors:  Ethan Ruh; Camille Johnson; Naomi Frankston; Shaquille Charles; William Anderst; Michael McClincy
Journal:  Clin Orthop Relat Res       Date:  2022-02-23       Impact factor: 4.755

5.  Effect of microseparation on contact mechanics in metal-on-metal hip replacements-A finite element analysis.

Authors:  Feng Liu; Sophie Williams; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-11-05       Impact factor: 3.368

6.  In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours.

Authors:  Y-M Kwon; S J Mellon; P Monk; D W Murray; H S Gill
Journal:  Bone Joint Res       Date:  2012-04-01       Impact factor: 5.853

7.  Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty.

Authors:  Francisco Romero; Farid Amirouche; Luke Aram; Mark H Gonzalez
Journal:  J Orthop Surg Res       Date:  2007-05-16       Impact factor: 2.359

8.  Friction in total hip joint prosthesis measured in vivo during walking.

Authors:  Philipp Damm; Joern Dymke; Robert Ackermann; Alwina Bender; Friedmar Graichen; Andreas Halder; Alexander Beier; Georg Bergmann
Journal:  PLoS One       Date:  2013-11-08       Impact factor: 3.240

9.  Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions.

Authors:  Xijin Hua; Junyan Li; Ling Wang; Zhongmin Jin; Ruth Wilcox; John Fisher
Journal:  J Biomech       Date:  2014-09-01       Impact factor: 2.712

Review 10.  Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Authors:  Guo-Liang Wu; Wei Zhu; Yan Zhao; Qi Ma; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628