Literature DB >> 11310176

Reduction in inflammation-induced sensitization of dorsal horn neurons by transcutaneous electrical nerve stimulation in anesthetized rats.

Y T Ma1, K A Sluka.   

Abstract

Transcutaneous electrical nerve stimulation (TENS) is utilized to treat a variety of painful conditions. Inflamed animals present with an increased response to noxious stimuli, i.e., hyperalgesia, at the site of injury (primary hyperalgesia) and outside the site of injury (secondary hyperalgesia). Further, following acute inflammation, dorsal horn neurons show an increased responsiveness to peripherally applied stimuli, which has been termed sensitization. Previous studies demonstrate a reduction in dorsal horn neuron activity following TENS treatment in normal animals and a reduction in primary and secondary hyperalgesia in acutely inflamed animals. The purpose of this study was to examine the effects of TENS on dorsal horn neurons sensitized by acute inflammation. Extracellular recordings from wide dynamic range (WDR), high threshold (HT) and low threshold (LT) dorsal horn neurons in anesthetized rats were assessed for spontaneous activity, responses to innocuous and noxious mechanical stimulation and receptive field size. Responses were measured before and 3 h after induction of inflammation, and immediately and 1 h after application of either high (100 Hz) or low (4 Hz) frequency TENS (motor intensity, pulse duration = 100 microseconds). TENS was applied to the inflamed paw to encompass the receptive field of the neuron for 20 min. WDR and HT dorsal horn neurons sensitized to mechanical stimulation after induction of inflammation. Application of either high or low frequency TENS to the inflamed paw reduced both innocuous and noxious evoked responses of WDR and HT dorsal horn neurons immediately and 1 h after treatment with TENS. Comparison of responses after TENS with baseline responses showed that the evoked responses in the majority of WDR and HT cells returned to or fell below baseline responses. TENS had no effect on responses of LT neurons. In summary, central neuron sensitization is reduced by TENS and may underlie the reduction in hyperalgesia observed after treatment with TENS.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11310176     DOI: 10.1007/s002210000629

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  28 in total

1.  Release of GABA and activation of GABA(A) in the spinal cord mediates the effects of TENS in rats.

Authors:  Y Maeda; T L Lisi; C G T Vance; K A Sluka
Journal:  Brain Res       Date:  2007-01-16       Impact factor: 3.252

Review 2.  Using TENS for pain control: the state of the evidence.

Authors:  Carol G T Vance; Dana L Dailey; Barbara A Rakel; Kathleen A Sluka
Journal:  Pain Manag       Date:  2014-05

3.  Wireless transcutaneous electrical nerve stimulation device for chemotherapy-induced peripheral neuropathy: an open-label feasibility study.

Authors:  Jennifer S Gewandter; Jenna Chaudari; Chinazom Ibegbu; Rachel Kitt; Jennifer Serventi; Joy Burke; Eva Culakova; Noah Kolb; Kathleen A Sluka; Mohamedtaki A Tejani; Nimish A Mohile
Journal:  Support Care Cancer       Date:  2018-08-27       Impact factor: 3.603

4.  What makes transcutaneous electrical nerve stimulation work? Making sense of the mixed results in the clinical literature.

Authors:  Kathleen A Sluka; Jan M Bjordal; Serge Marchand; Barbara A Rakel
Journal:  Phys Ther       Date:  2013-05-02

5.  Transcutaneous electrical nerve stimulation for the control of pain during rehabilitation after total knee arthroplasty: A randomized, blinded, placebo-controlled trial.

Authors:  Barbara A Rakel; M Bridget Zimmerman; Katharine Geasland; Jennie Embree; Charles R Clark; Nicolas O Noiseux; John J Callaghan; Keela Herr; Deirdre Walsh; Kathleen A Sluka
Journal:  Pain       Date:  2014-09-28       Impact factor: 6.961

6.  IMPROVED PRESSURE PAIN THRESHOLDS AND FUNCTION FOLLOWING NOXIOUS ELECTRICAL STIMULATION ON A RUNNER WITH CHRONIC ACHILLES TENDINOPATHY: A CASE REPORT.

Authors:  Brian J Eckenrode; Scott K Stackhouse
Journal:  Int J Sports Phys Ther       Date:  2015-06

Review 7.  A Mechanism-Based Approach to Physical Therapist Management of Pain.

Authors:  Ruth L Chimenti; Laura A Frey-Law; Kathleen A Sluka
Journal:  Phys Ther       Date:  2018-05-01

8.  A new transient sham TENS device allows for investigator blinding while delivering a true placebo treatment.

Authors:  Barbara Rakel; Nicholas Cooper; Heather J Adams; Bryan R Messer; Laura A Frey Law; Douglas R Dannen; Carrie A Miller; Anya C Polehna; Rachelle C Ruggle; Carol G T Vance; Deirdre M Walsh; Kathleen A Sluka
Journal:  J Pain       Date:  2009-11-27       Impact factor: 5.820

9.  Transcutaneous electrical nerve stimulation at both high and low frequencies activates ventrolateral periaqueductal grey to decrease mechanical hyperalgesia in arthritic rats.

Authors:  J M DeSantana; L F S Da Silva; M A De Resende; K A Sluka
Journal:  Neuroscience       Date:  2009-07-02       Impact factor: 3.590

10.  Effect of transcutaneous electrical nerve stimulation on pain, function, and quality of life in fibromyalgia: a double-blind randomized clinical trial.

Authors:  Brian Noehren; Dana L Dailey; Barbara A Rakel; Carol G T Vance; Miriam B Zimmerman; Leslie J Crofford; Kathleen A Sluka
Journal:  Phys Ther       Date:  2014-09-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.