Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques.

G Schmalisch1, B Foitzik, R R Wauer, J Stocks.   

Abstract

Commercial devices for tidal breathing measurements in newborns allow only short-term measurements, due to the high apparatus dead space of the face mask and pneumotachometer. The flow-through technique (FTT) minimizes the dead space by a background flow, thereby allowing long-term measurements. The aim of this study was to investigate the comparability of tidal breathing parameters using both techniques. Paired measurements of tidal breathing were performed in 86 sleeping infants (median (range) body weight 2.8 kg (1.9-5.3 kg), age 65 days (3-150 days)), using the FTT and SensorMedics 2600 (SM 2600). There was a significant bias (p <0.001) in all tidal breathing parameters. Compared with the FTT, increases (95% confidence interval (CI)) in tidal volume (VT), respiratory frequency (fR), and minute ventilation (V'E) were 0.74 (0.5-1.0) mL.kg(-1), 9.0 (6.9-11.2).min(-1) and 92 (74-109) mL.min(-1).kg(-1) when measured with the SM 2600, representing average increases of 13, 17 and 30%, respectively, in response to the added dead space. By contrast, time to peak tidal expiratory flow as a proportion of expiratory time (tPTEF/tE) was changed by -0.09 (-0.11-0.08). The mean (95% CI) change in tPTEF/tE of -54 (-62-45)%, when measured in infants by the SM 2600, was remarkably similar to that observed during in vitro validation studies (-59 (-73-44)%), suggesting that the discrepancies in timing parameters may be largely attributable to differences in signal processing. In conclusion, differences in measurement technique and precision of the devices used can result in significant differences in tidal breathing parameters. This may impede the comparison of results within and between infants and the clinical interpretation of tidal breathing measurements in newborns.

Entities:  

Mesh:

Year:  2001        PMID: 11307739     DOI: 10.1183/09031936.01.17101080

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  11 in total

1.  Comparison of two different CPAP systems by tidal breathing parameters.

Authors:  Thomas Hückstädt; Bertram Foitzik; Roland R Wauer; Gerd Schmalisch
Journal:  Intensive Care Med       Date:  2003-05-27       Impact factor: 17.440

2.  Novel technique to average breathing loops for infant respiratory function testing.

Authors:  G Schmalisch; M Schmidt; B Foitzik
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

3.  Early lung function testing in infants with aortic arch anomalies identifies patients at risk for airway obstruction.

Authors:  Charles Christoph Roehr; Silke Wilitzki; Bernd Opgen-Rhein; Karim Kalache; Hans Proquitté; Christoph Bührer; Gerd Schmalisch
Journal:  PLoS One       Date:  2011-09-23       Impact factor: 3.240

4.  Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: longitudinal assessment during the first 15 months of corrected age.

Authors:  Gerd Schmalisch; Silke Wilitzki; Charles Christoph Roehr; Hans Proquitté; Christoph Bührer
Journal:  BMC Pediatr       Date:  2012-03-23       Impact factor: 2.125

5.  Differences in tidal breathing between infants with chronic lung diseases and healthy controls.

Authors:  G Schmalisch; S Wilitzki; R R Wauer
Journal:  BMC Pediatr       Date:  2005-09-08       Impact factor: 2.125

6.  Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

Authors:  Snorri Donaldsson; Markus Falk; Baldvin Jonsson; Thomas Drevhammar
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

7.  Electromagnetic inductance plethysmography is well suited to measure tidal breathing in infants.

Authors:  Mariann H L Bentsen; Morten Eriksen; Merete S Olsen; Trond Markestad; Thomas Halvorsen
Journal:  ERJ Open Res       Date:  2016-11-24

8.  Lung function in very low birth weight infants after pharmacological and surgical treatment of patent ductus arteriosus - a retrospective analysis.

Authors:  Payman Barikbin; Hannes Sallmon; Silke Wilitzki; Joachim Photiadis; Christoph Bührer; Petra Koehne; Gerd Schmalisch
Journal:  BMC Pediatr       Date:  2017-01-06       Impact factor: 2.125

Review 9.  Current methodological and technical limitations of time and volumetric capnography in newborns.

Authors:  Gerd Schmalisch
Journal:  Biomed Eng Online       Date:  2016-08-30       Impact factor: 2.819

10.  Lung function at term in extremely preterm-born infants: a regional prospective cohort study.

Authors:  Mariann Haavik Bentsen; Trond Markestad; Knut Øymar; Thomas Halvorsen
Journal:  BMJ Open       Date:  2017-10-25       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.