BACKGROUND: Saline cooling of the electrode during radiofrequency (RF) ablation increases lesion size in animal models. If cooled RF also increases lesion size in human infarcts, it should facilitate the termination of ventricular tachycardia (VT). METHODS AND RESULTS: In 66 patients with VT due to prior infarction, 366 ablation sites, which were classified by entrainment and isolated potentials followed by ablation during VT with either standard RF energy (247 sites) or cooled RF (119 sites), were retrospectively reviewed to compare the efficacy for terminating VT. RF energy was applied at 259 isthmus sites, 62 bystander sites, 28 inner loop sites, and 17 outer loop sites. Compared with standard RF, cooled RF terminated VT more frequently at isthmus sites where an isolated potential was present (89% versus 54%, P=0.003), isthmus sites without an isolated potential (36% versus 21%, P=0.04), and at inner loop sites (60% versus 22%, P=0.04). Termination rates were similarly low for cooled and standard RF at bystander sites (14% versus 9%, P=0.56) and outer loop sites (13% versus 11%, P=0.93). CONCLUSIONS: Greater efficacy of cooled RF for terminating VT is consistent with the production of a larger lesion in human infarctions, which should facilitate successful ablation.
BACKGROUND:Saline cooling of the electrode during radiofrequency (RF) ablation increases lesion size in animal models. If cooled RF also increases lesion size in humaninfarcts, it should facilitate the termination of ventricular tachycardia (VT). METHODS AND RESULTS: In 66 patients with VT due to prior infarction, 366 ablation sites, which were classified by entrainment and isolated potentials followed by ablation during VT with either standard RF energy (247 sites) or cooled RF (119 sites), were retrospectively reviewed to compare the efficacy for terminating VT. RF energy was applied at 259 isthmus sites, 62 bystander sites, 28 inner loop sites, and 17 outer loop sites. Compared with standard RF, cooled RF terminated VT more frequently at isthmus sites where an isolated potential was present (89% versus 54%, P=0.003), isthmus sites without an isolated potential (36% versus 21%, P=0.04), and at inner loop sites (60% versus 22%, P=0.04). Termination rates were similarly low for cooled and standard RF at bystander sites (14% versus 9%, P=0.56) and outer loop sites (13% versus 11%, P=0.93). CONCLUSIONS: Greater efficacy of cooled RF for terminating VT is consistent with the production of a larger lesion in humaninfarctions, which should facilitate successful ablation.
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: J Interv Card Electrophysiol Date: 2012-03 Impact factor: 1.900
Authors: Jonathan Weinstock; Paul J Wang; Munther K Homoud; Mark S Link; N A Mark Estes Journal: J Interv Card Electrophysiol Date: 2003-10 Impact factor: 1.900
Authors: Benhur Davi Henz; Thais A do Nascimento; Cristiano de O Dietrich; Charles Dalegrave; Veruska Hernandes; Cezar E Mesas; Luiz R Leite; Claudio Cirenza; Samuel J Asirvatham; Angelo Amato Vincenzo de Paola Journal: J Interv Card Electrophysiol Date: 2009-09-15 Impact factor: 1.900
Authors: Hafiza H Khan; William H Maisel; Carolyn Ho; Makoto Suzuki; Kyoko Soejima; Scott Solomon; William G Stevenson Journal: J Interv Card Electrophysiol Date: 2002-12 Impact factor: 1.900