Literature DB >> 11293910

Automated urinalysis. Evaluation of the Sysmex UF-50.

H Okada1, Y Sakai, G Kawabata, M Fujisawa, S Arakawa, Y Hamaguchi, S Kamidono.   

Abstract

We assessed the Sysmex UF-50 for reproducibility of results and carryover rate by performing between- and within-run precision analyses on 315 urine samples, evaluated the feasibility of using the UF-50 to measure urinary cellular and noncellular components by comparing results from the UF-50 with results of manual urinalysis using the Kova system, and performed side-by-side comparison of the within-run reproducibility from the UF-50, the UF-100, and the Kova system. Results from the UF-50 and UF-100 were highly reproducible, and the carryover rate was 0.5% or less for the urinary components. In between-run precision assays, the coefficients of variation for UF-50 results for all cellular components were less than 10%. The agreement (gamma statistics) between values from the UF-50 and the Kova system was excellent for RBC, WBC, and bacterial counts. The cell counts from the UF-50 for RBCs, WBCs, epithelial cells, and bacteria were 52%, 63%, 54%, and 110%, respectively, of those measured by manual urinalysis. The UF-50 performed quantitative analysis in 72 seconds, compared with 330 seconds for manual methods. The UF-50 is suitable for the first screening to detect hematuria, pyuria, and bacteriuria.

Entities:  

Mesh:

Year:  2001        PMID: 11293910     DOI: 10.1309/RT7X-EMGF-G8AV-TGJ8

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  5 in total

1.  Determination of cut-off values for leucocytes and bacteria for urine flow cytometer (UF-100) in urinary tract infections.

Authors:  Tulay Koken; Orhan C Aktepe; Mustafa Serteser; Murat Samli; Ahmet Kahraman; Nurhan Dogan
Journal:  Int Urol Nephrol       Date:  2002       Impact factor: 2.370

2.  Enumeration of bacterial cell numbers and detection of significant bacteriuria by use of a new flow cytometry-based device.

Authors:  Hiroshi Okada; Toshiro Shirakawa; Akinobu Gotoh; Yutaka Kamiyama; Satoru Muto; Hisamitsu Ide; Yukio Hamaguchi; Shigeo Horie
Journal:  J Clin Microbiol       Date:  2006-10       Impact factor: 5.948

3.  Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy.

Authors:  Ebubekir Bakan; Nurinnisa Ozturk; Nurcan Kilic Baygutalp; Elif Polat; Kadriye Akpinar; Emrullah Dorman; Harun Polat; Nuri Bakan
Journal:  Biochem Med (Zagreb)       Date:  2016-10-15       Impact factor: 2.313

4.  A new concept and a comprehensive evaluation of SYSMEX UF-1000i  flow cytometer to identify culture-negative urine specimens in patients with UTI.

Authors:  T Monsen; P Ryden
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-04-06       Impact factor: 3.267

5.  UF-5000 flow cytometer: A new technology to support microbiologists' interpretation of suspected urinary tract infections.

Authors:  Roberto Ippoliti; Isabella Allievi; Andrea Rocchetti
Journal:  Microbiologyopen       Date:  2020-01-06       Impact factor: 3.139

  5 in total