Literature DB >> 11287540

Value of three-dimensional US for optimizing guidance for ablating focal liver tumors.

S C Rose1, T I Hassanein, D W Easter, R A Gamagami, M Bouvet, D H Pretorius, T R Nelson, T B Kinney, G M James.   

Abstract

PURPOSE: To determine if three-dimensional ultrasound (3D US), by nature of its ability to simultaneously evaluate structures in three orthogonal planes and to study relationships of devices to tumor(s) and surrounding anatomic structures from any desired orientation, adds significant additional information to real-time 2D US used for placement of devices for ablation of focal liver tumors.
MATERIALS AND METHODS: Sixteen patients underwent focal ablation of 23 liver tumors during two intraoperative cryoablation (CA) procedures, three intraoperative radiofrequency ablation (RFA) procedures, 11 percutaneous ethanol injections (PEI) procedures, and six percutaneous RFA procedures. After satisfactory placement of the ablative device(s) with 2D US guidance, 3D US was used to reevaluate adequacy to device position. Information added by 3D US and resultant alterations in device deployment were tabulated.
RESULTS: 3D US added information in 20 of 22 (91%) procedures and caused the operator to readjust the number or position of ablative devices in 10 of 22 (45%) of procedures. Specifically, 3D US improved visualization and confident localization of devices in 13 of 22 (59%) procedures, detected unacceptable device placement in 10 of 22 (45%), and determined that 2D US had incorrectly predicted device orientation to a tumor in three of 22 (14%).
CONCLUSIONS: Compared to conventional 2D US, 3D US provides additional relationship information for improved placement and optimal distribution of ablative agents for treatment of focal liver malignancy.

Entities:  

Mesh:

Year:  2001        PMID: 11287540     DOI: 10.1016/s1051-0443(07)61892-2

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  13 in total

Review 1.  Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors.

Authors:  Stefaan Mulier; Yicheng Ni; Jacques Jamart; Theo Ruers; Guy Marchal; Luc Michel
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

2.  [Transcutaneous ultrasound].

Authors:  M Hünerbein; S S Chopra; P M Schlag
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

3.  In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography.

Authors:  Brian J Fahey; Rendon C Nelson; Stephen J Hsu; David P Bradway; Douglas M Dumont; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2008-05-09       Impact factor: 2.998

4.  Case-control study of the RFA therapeutic effect of newly developed 4D US and conventional 2D US.

Authors:  Atsunori Kusakabe; Shunsuke Nojiri; Etsuko Iio; Kentaro Matsuura; Noboru Shinkai; Tomokatsu Miyaki; Takashi Joh
Journal:  J Med Ultrason (2001)       Date:  2012-07-31       Impact factor: 1.314

5.  Laparoscopic microwave ablation of human liver tumours using a novel three-dimensional magnetic guidance system.

Authors:  David Sindram; Kerri A Simo; Ryan Z Swan; Sharif Razzaque; David J Niemeyer; Ramanathan M Seshadri; Erin Hanna; Iain H McKillop; David A Iannitti; John B Martinie
Journal:  HPB (Oxford)       Date:  2014-09-17       Impact factor: 3.647

Review 6.  Locoregional therapies for hepatocellular carcinoma: a critical review from the surgeon's perspective.

Authors:  Ronnie Tung-Ping Poon; Sheung-Tat Fan; Flora Hau-Fung Tsang; John Wong
Journal:  Ann Surg       Date:  2002-04       Impact factor: 12.969

7.  Real-time three-dimensional guided ultrasound targeting system for microwave ablation of liver tumours: a human pilot study.

Authors:  David Sindram; Ryan Z Swan; Kwan N Lau; Iain H McKillop; David A Iannitti; John B Martinie
Journal:  HPB (Oxford)       Date:  2011-01-27       Impact factor: 3.647

8.  Contrast-enhanced 3D ultrasound in the radiofrequency ablation of liver tumors.

Authors:  Edward Leen; Senthil Kumar; Shahid A Khan; Gavin Low; Keh Oon Ong; Paul Tait; Mike Averkiou
Journal:  World J Gastroenterol       Date:  2009-01-21       Impact factor: 5.742

9.  Imaging detection of new HCCs in cirrhotic patients treated with different techniques: Comparison of conventional US, spiral CT, and 3-dimensional contrast-enhanced US with the Navigator technique (Nav 3D CEUS)().

Authors:  F Giangregorio; G Comparato; M G Marinone; M Di Stasi; G Sbolli; G Aragona; P Tansini; F Fornari
Journal:  J Ultrasound       Date:  2009-02-26

10.  In vivo visualization of abdominal malignancies with acoustic radiation force elastography.

Authors:  B J Fahey; R C Nelson; D P Bradway; S J Hsu; D M Dumont; G E Trahey
Journal:  Phys Med Biol       Date:  2007-12-19       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.