Extension of generator longevity by use of high impedance ventricular leads.

M Scherer1, K Ezziddin, A Klesius, M Skupin, S Helms, A Moritz, H G Olbrich.   

Abstract

The resistance of a pacing lead negatively correlates to current consumption. A prospective, randomized trial was conducted to evaluate the effect of a high impedance ventricular lead (CapSure Z) on generator longevity compared to a conventional lead (CapSure SP) eighty-nine patients were included in the study (51 male, 37 female, age 70.0+/-10.3 years). Forty-six patients received a CapSure SP lead (5024 bipolar), and 43 patients received a CapSure Z lead (5034 bipolar) in a randomized fashion. Follow-up data collected at 5 days, 3, 6, and 12 months postimplant included: lead impedance, pacing and sensing thresholds, impulse energy, and estimated time to replacement. All parameters were collected via pacemaker telemetry; the time to replacement was calculated automatically by a programmed algorithm of the pacemaker. There was no difference in the performance of the atrial lead when a dual chamber device was indicated. The CapSure Z leads displayed statistically significant higher impedance values than the CapSure SP lead in all follow-up periods. There was no significant difference in lead related complications. No significant differences were observed between pacing and sensing thresholds in both groups. The CapSure Z leads provided a significant reduction in current drain, resulting in a reduction of mean energy consumption at the 12-month follow-up from 10.4+/-5.0 microJ in the CapSure SP group to 6.6+/-1.4 microJ in the CapSure Z group (median from 9.9 microJ to 6.9 microJ, respectively), providing an estimated increase in mean longevity of more than 1 year from 81.1+/-23.5 months in the CapSure SP group to 94.5+/-13.4 months in the CapSure Z group (median: 76.5 months to 95.0 months, respectively). The use of a high resistance lead for ventricular pacing appears to result in a clinically relevant extension of generator longevity.

Entities:  

Mesh:

Year:  2001        PMID: 11270701     DOI: 10.1046/j.1460-9592.2001.00206.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Pacemaker longevity: the world's longest-lasting VVI pacemaker.

Authors:  David Katz; Toshio Akiyama
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-07       Impact factor: 1.468

2.  Combining current of injury and P-wave sensing optimized right atrial active-fixation leads implantation.

Authors:  Meng-Rong Chen; Fei-Long Zhang; Wei-Wei Wang; Xue-Hai Chen; Jian-Hua Chen; Liang-Long Chen
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.