Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs.

R Luechinger1, F Duru, M B Scheidegger, P Boesiger, R Candinas.   

Abstract

Magnetic resonance imaging (MRI) is a widely accepted tool for the diagnosis of a variety of disease states. However, the presence of an implanted pacemaker is considered to be a strict contraindication to MRI in a vast majority of centers due to safety concerns. In phantom studies, the authors investigated the force and torque effects of the static magnetic field of MRI on pacemakers and ICDs. Thirty-one pacemakers (15 dual chamber and 16 single chamber units) from eight manufacturers and 13 ICDs from four manufacturers were exposed to the static magnetic field of a 1.5-Tesla MRI scanner. Magnetic force and acceleration measurements were obtained quantitatively, and torque measurements were made qualitatively. For pacemakers, the measured magnetic force was in the range of 0.05-3.60 N. Pacemakers released after 1995 had low magnetic force values as compared to the older devices. For these devices, the measured acceleration was even lower than the gravity of the earth (< 9.81 N/kg). Likewise, the torque levels were significantly reduced in newer generation pacemakers (< or = 2 from a scale of 6). ICD devices, except for one recent model, showed higher force (1.03-5.85 N), acceleration 9.5-34.2 N/kg), and torque (5-6 out of 6) levels. In conclusion, modern pacemakers present no safety risk with respect to magnetic force and torque induced by the static magnetic field of a 1.5-Tesla MRI scanner. However, ICD devices, despite considerable reduction in size and weight, may still pose problems due to strong magnetic force and torque.

Entities:  

Mesh:

Year:  2001        PMID: 11270700     DOI: 10.1046/j.1460-9592.2001.00199.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  26 in total

1.  Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach.

Authors:  Barry Anthony Boilson; Anita Wokhlu; Nancy G Acker; Joel P Felmlee; Robert E Watson; Paul R Julsrud; Paul A Friedman; Yong-Mei Cha; Robert F Rea; David L Hayes; Win-Kuang Shen
Journal:  J Interv Card Electrophysiol       Date:  2011-09-21       Impact factor: 1.900

2.  Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

Authors:  Ariel Roguin; Menekhem M Zviman; Glenn R Meininger; E Rene Rodrigues; Timm M Dickfeld; David A Bluemke; Albert Lardo; Ronald D Berger; Hugh Calkins; Henry R Halperin
Journal:  Circulation       Date:  2004-07-26       Impact factor: 29.690

3.  A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

Authors:  Peter Thomas Burke; Hamid Ghanbari; Patrick B Alexander; Michael K Shaw; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2010-01-29       Impact factor: 1.900

4.  Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective.

Authors:  M J W Götte; I K Rüssel; G J de Roest; T Germans; R F Veldkamp; P Knaapen; C P Allaart; A C van Rossum
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

5.  Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study.

Authors:  Alexander Pfeil; Stefanie Drobnik; Reinhard Rzanny; Anas Aboud; Joachim Böttcher; Peter Schmidt; Christian Ortmann; Gita Mall; Khosro Hekmat; Bernhard Brehm; Juergen Reichenbach; Thomas E Mayer; Gunter Wolf; Andreas Hansch
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

6.  Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study.

Authors:  Mrinal Yadava; Matthew Nugent; Angela Krebsbach; Jessica Minnier; Peter Jessel; Charles A Henrikson
Journal:  J Interv Card Electrophysiol       Date:  2017-07-22       Impact factor: 1.900

Review 7.  Safety of implanted cardiac devices in an MRI environment.

Authors:  Esra Gucuk Ipek; Saman Nazarian
Journal:  Curr Cardiol Rep       Date:  2015-07       Impact factor: 2.931

8.  3-T MRI safety assessments of magnetic dental attachments and castable magnetic alloys.

Authors:  M Hasegawa; K Miyata; Y Abe; T Ishii; T Ishigami; K Ohtani; E Nagai; T Ohyama; Y Umekawa; S Nakabayashi
Journal:  Dentomaxillofac Radiol       Date:  2015-03-18       Impact factor: 2.419

9.  Forces on cardiac implantable electronic devices during remote magnetic navigation.

Authors:  C Jilek; C Lennerz; B Stracke; H Badran; V Semmler; T Reents; S Ammar; S Fichtner; B Haller; G Hessling; I Deisenhofer; C Kolb
Journal:  Clin Res Cardiol       Date:  2012-09-29       Impact factor: 5.460

10.  [Pacemaker and MRI in clinical practice].

Authors:  A Fendt; M Strauß; K Kouraki; R Zahn; T Kleemann
Journal:  Herz       Date:  2018-11       Impact factor: 1.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.