Geometrical factors affecting the interindividual variability of the ECG and the VCG.

A van Oosterom1, R Hoekema, G J Uijen.   

Abstract

Various measures for quantifying the interindividual variability of the electrocardiogram and the vectorcardiogram in healthy subjects are presented. An analysis of factors that may cause this variability is performed, in particular of the geometrical factors of body size, heart size, heart position, and orientation. The results indicate that the variations in the magnitude of the electrocardiogram as observed through leads placed on the anterior thorax are dominated by the solid angle at which the outline of ventricular mass is seen from points on the thorax. Heart size and body size as such play only a secondary role. The limited spatial sampling of the anterior thorax directly overlaying the heart causes the mean values of all measures of amplitudes in women to be lower than in men. The vectorcardiogram magnitude was found to be much less dependent on overall geometry and heart position, and, hence, also to be less dependent on gender.

Entities:  

Mesh:

Year:  2000        PMID: 11265725     DOI: 10.1054/jelc.2000.20356

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  10 in total

1.  Calibration of Cohorts of Virtual Patient Heart Models Using Bayesian History Matching.

Authors:  Cristobal Rodero; Stefano Longobardi; Christoph Augustin; Marina Strocchi; Gernot Plank; Pablo Lamata; Steven A Niederer
Journal:  Ann Biomed Eng       Date:  2022-10-21       Impact factor: 4.219

Review 2.  Sex differences in cardiac autonomic regulation and in repolarisation electrocardiography.

Authors:  Peter Smetana; Marek Malik
Journal:  Pflugers Arch       Date:  2013-02-13       Impact factor: 3.657

3.  The Reconstruction of a 12-Lead Electrocardiogram from a Reduced Lead Set Using a Focus Time-Delay Neural Network.

Authors:  Gerard H Smith; Dawie J Van den Heever; Wayne Swart
Journal:  Acta Cardiol Sin       Date:  2021-01       Impact factor: 2.672

4.  Gender differences in stability of the instantaneous patterns of body surface potentials during ventricular repolarisation.

Authors:  A D Corlan; P W Macfarlane; L De Ambroggi
Journal:  Med Biol Eng Comput       Date:  2003-09       Impact factor: 3.079

5.  The association of spatial T wave axis deviation with incident coronary events. The ARIC cohort.

Authors:  Georgeta D Vaidean; Pentti M Rautaharju; Ronald J Prineas; Eric A Whitsel; Lloyd E Chambless; Aaron R Folsom; Wayne D Rosamond; Zhu-Ming Zhang; Richard S Crow; Gerardo Heiss
Journal:  BMC Cardiovasc Disord       Date:  2005-01-11       Impact factor: 2.298

Review 6.  Individual identification via electrocardiogram analysis.

Authors:  Antonio Fratini; Mario Sansone; Paolo Bifulco; Mario Cesarelli
Journal:  Biomed Eng Online       Date:  2015-08-14       Impact factor: 2.819

7.  Towards a Continuous Biometric System Based on ECG Signals Acquired on the Steering Wheel.

Authors:  João Ribeiro Pinto; Jaime S Cardoso; André Lourenço; Carlos Carreiras
Journal:  Sensors (Basel)       Date:  2017-09-28       Impact factor: 3.576

8.  Development, calibration, and validation of a novel human ventricular myocyte model in health, disease, and drug block.

Authors:  Jakub Tomek; Alfonso Bueno-Orovio; Elisa Passini; Xin Zhou; Ana Minchole; Oliver Britton; Chiara Bartolucci; Stefano Severi; Alvin Shrier; Laszlo Virag; Andras Varro; Blanca Rodriguez
Journal:  Elife       Date:  2019-12-24       Impact factor: 8.140

9.  The effect of precordial lead displacement on ECG morphology.

Authors:  Michał Kania; Hervé Rix; Małgorzata Fereniec; Heriberto Zavala-Fernandez; Dariusz Janusek; Tomasz Mroczka; Günter Stix; Roman Maniewski
Journal:  Med Biol Eng Comput       Date:  2013-10-19       Impact factor: 2.602

10.  MRI-Based Computational Torso/Biventricular Multiscale Models to Investigate the Impact of Anatomical Variability on the ECG QRS Complex.

Authors:  Ana Mincholé; Ernesto Zacur; Rina Ariga; Vicente Grau; Blanca Rodriguez
Journal:  Front Physiol       Date:  2019-08-27       Impact factor: 4.566

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.