Literature DB >> 11251261

Fatigue testing median sternotomy closures.

A R Casha1, M Gauci, L Yang, M Saleh, P H Kay, G J Cooper.   

Abstract

OBJECTIVE: Sternal dehiscence is commonly due to wire cutting through bone. With a biological model, we measured the rate of cutting through bone, of standard steel wire closure, peristernal steel wire, figure-of-eight closure, polyester and sternal bands sternotomy closure techniques.
METHODS: Polyester, figure-of-eight, peristernal and sternal band closures were tested against standard closure eight times using adjacent paired samples, to eliminate biological variables. Fatigue testing was performed by a computerized materials-testing machine, cycling between loads of 1 and 10 kg. The displacements at maximum and minimum loads were measured during each cycle. Cutting through, manifested by the displacement at the maximum load between the 1st and 150th cycles was measured. The percentage cut-through of each closure method versus standard closure was calculated.
RESULTS: The differences in the displacement between each of the polyester (1.01 mm), figure-of-eight (0.52 mm), peristernal (0.72 mm) and sternal band (0.66 mm) groups versus standard closure (0.22, 0.22, 2.1, 3.2 mm) in the paired samples were statistically significant (Student's paired t-test; P<0.01). There were statistically significant differences in the percentage cut-through of polyester, figure-of-eight, peristernal and sternal bands (ANOVA, P<0.001), versus standard closure.
CONCLUSIONS: In our sheep sternum model, we have quantified the differing rate of cutting through bone of five types of median sternotomy closure techniques. We have controlled for bone variables by testing each closure versus standard closure using paired adjacent bone samples. Peristernal and sternal band closure techniques are significantly superior to standard closure. The use of polyester and figure-of-eight closures requires caution.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11251261     DOI: 10.1016/s1010-7940(01)00584-x

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  7 in total

1.  Biomechanical analysis of the FlatWire Figure 8 sternal fixation device.

Authors:  Ryan M Wilson; Paul A Ghareeb; W Thomas McClellan; Ashley N Boustany
Journal:  Plast Surg (Oakv)       Date:  2014       Impact factor: 0.947

2.  Placement of trans-sternal wires according to an ellipsoid pressure vessel model of sternal forces.

Authors:  Aaron R Casha; Alex Manché; Marilyn Gauci; Marie-Therese Camilleri-Podesta; Pierre Schembri-Wismayer; Zdenka Sant; Ruben Gatt; Joseph N Grima
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-12-20

3.  Nitinol thermoreactive clips for secondary sternal closure in cases of noninfective sternal dehiscence.

Authors:  Arif Gucu; Faruk Toktas; Cuneyt Eris; Yusuf Ata; Tamer Turk
Journal:  Tex Heart Inst J       Date:  2012

4.  Fatigue testing of three peristernal median sternotomy closure techniques.

Authors:  Cameron Wangsgard; David J Cohen; Lanny V Griffin
Journal:  J Cardiothorac Surg       Date:  2008-09-24       Impact factor: 1.637

5.  Prospective, randomized, single blinded pilot study of a new FlatWire based sternal closure system.

Authors:  Ashley N Boustany; Paul Ghareeb; Kee Lee
Journal:  J Cardiothorac Surg       Date:  2014-06-02       Impact factor: 1.637

6.  Outcomes following the implementation of a quality control campaign to decrease sternal wound infections after coronary artery by-pass grafting.

Authors:  Rickard P F Lindblom; Birgitta Lytsy; Camilla Sandström; Nadjira Ligata; Beata Larsson; Ulrika Ransjö; Christine Leo Swenne
Journal:  BMC Cardiovasc Disord       Date:  2015-11-17       Impact factor: 2.298

7.  Retrospective analysis of the impact of sternum closure technique on postoperative comfort and rehabilitation.

Authors:  Leszek Kukulski; Aleksandra Krawczyk; Jerzy Pacholewicz
Journal:  Kardiochir Torakochirurgia Pol       Date:  2018-12-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.