Literature DB >> 22949767

Nitinol thermoreactive clips for secondary sternal closure in cases of noninfective sternal dehiscence.

Arif Gucu1, Faruk Toktas, Cuneyt Eris, Yusuf Ata, Tamer Turk.   

Abstract

Postoperative sternal dehiscence is a potentially catastrophic sequela to median sternotomy that can cause not only chest-wall discomfort and pulmonary dysfunction but infection, both superficial and mediastinal. Nitinol thermoreactive clips use a novel material in the treatment of sternal dehiscence. We sought to determine whether the use of these clips is an effective remedy for noninfective sternal dehiscence. From January 2008 through December 2011, we retrospectively studied the data on 10 patients whose sternums had been closed with nitinol thermoreactive clips after the development of noninfective sternal dehiscence. Diagnosis was made on the bases of clinical criteria, chest radiography, and microbiological investigation. There was no control group. No procedure-related sequelae occurred. There was no recurrent sternal instability and dehiscence, sternal-related hemorrhage, superficial wound infection, or mediastinal infection. We believe that the use of nitinol thermoreactive clips is a safe, easy, and efficient method of secondary sternal closure for noninfective sternal dehiscence.

Entities:  

Keywords:  Biocompatible materials; bone wires; postoperative complications; reoperation; retrospective studies; sternotomy, median; sternum/surgery; surgical wound dehiscence/prevention & control/surgery; suture techniques; sutures; thoracotomy/adverse effects

Mesh:

Substances:

Year:  2012        PMID: 22949767      PMCID: PMC3423269     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  20 in total

1.  Sternal instability after midline sternotomy.

Authors:  F Robicsek; A Fokin; J Cook; D Bhatia
Journal:  Thorac Cardiovasc Surg       Date:  2000-02       Impact factor: 1.827

Review 2.  Disruption and infection of median sternotomy: a comprehensive review.

Authors:  Julian E Losanoff; Bruce W Richman; James W Jones
Journal:  Eur J Cardiothorac Surg       Date:  2002-05       Impact factor: 4.191

3.  Sternal closure using semirigid fixation with thermoreactive clips.

Authors:  Paolo Centofanti; Michele La Torre; Luciano Barbato; Alessandro Verzini; Francesco Patanè; Michele di Summa
Journal:  Ann Thorac Surg       Date:  2002-09       Impact factor: 4.330

4.  Interlocking figure-of-8 closure of the sternum.

Authors:  R F Di Marco; M W Lee; S Bekoe; K J Grant; G F Woelfel; R V Pellegrini
Journal:  Ann Thorac Surg       Date:  1989-06       Impact factor: 4.330

5.  Repair of refractory sternal dehiscence: a new technique.

Authors:  C D Campo; R O Heimbecker
Journal:  J Thorac Cardiovasc Surg       Date:  1982-06       Impact factor: 5.209

6.  Prospective evaluation of a new sternal closure method with thermoreactive clips.

Authors:  A Negri; J Manfredi; A Terrini; G Rodella; G Bisleri; S El Quarra; C Muneretto
Journal:  Eur J Cardiothorac Surg       Date:  2002-10       Impact factor: 4.191

7.  A modified parasternal wire technique for prevention and treatment of sternal dehiscence.

Authors:  Rajeev Sharma; Deepak Puri; Bishnu P Panigrahi; Inderjeet S Virdi
Journal:  Ann Thorac Surg       Date:  2004-01       Impact factor: 4.330

8.  Transverse sternal plating in secondary sternal reconstruction.

Authors:  Joseph Huh; Faisal Bakaeen; Danny Chu; Matthew J Wall
Journal:  J Thorac Cardiovasc Surg       Date:  2008-08-15       Impact factor: 5.209

9.  Postoperative median sternotomy dehiscence.

Authors:  A Harjula; A Järvinen
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1983

10.  Faulty sternotomy and complications after median sternotomy.

Authors:  R Shafir; J Weiss; O Herman; N Cohen; D Stern; Y Igra
Journal:  J Thorac Cardiovasc Surg       Date:  1988-08       Impact factor: 5.209

View more
  1 in total

1.  Comparison of Two Sternal Closure Techniques Based on Risk Factors: A Prospective, Observational Study.

Authors:  Ali Cemal Duzgun; Ekin Ilkeli; Fehmi Katircioglu
Journal:  Appl Bionics Biomech       Date:  2021-10-08       Impact factor: 1.781

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.