Literature DB >> 11250640

Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection.

M Abreu1, A Mol, J B Ludlow.   

Abstract

OBJECTIVE: A high-resolution charge-coupled device was used to compare the diagnostic performances obtained with Trophy's new RVGui sensor and Kodak Ektaspeed Plus film with respect to caries detection. STUDY
DESIGN: Three acquisition modes of the Trophy RVGui sensor were compared with Kodak Ektaspeed Plus film. Images of the proximal surfaces of 40 extracted posterior teeth were evaluated by 6 observers. The presence or absence of caries was scored by means of a 5-point confidence scale. The actual caries status of each surface was determined through ground-section histology. Responses were evaluated by means of receiver operating characteristic analysis. Areas under receiver operating characteristic curves (A(Z)) were assessed through analysis of variance.
RESULTS: The mean A(Z) scores were 0.85 for film, 0.84 for the high-resolution caries mode, and 0.82 for both the low resolution caries mode and the high-resolution periodontal mode. These differences were not statistically significant (P =.70). The differences among observers also were not statistically significant (P =.23).
CONCLUSION: The performance of the RVGui sensor in high- and low-resolution modes for proximal caries detection is comparable to that of Ektaspeed Plus film.

Mesh:

Year:  2001        PMID: 11250640     DOI: 10.1067/moe.2001.112393

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  8 in total

1.  Accuracy of direct digital radiography for detecting occlusal caries in primary teeth compared with conventional radiography and visual inspection: an in vitro study.

Authors:  P R Dias da Silva; M Martins Marques; W Steagall; F Medeiros Mendes; C A Lascala
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

2.  In vitro comparison of digital and conventional bitewing radiographs for the detection of approximal caries in primary teeth exposed and viewed by a new wireless handheld unit.

Authors:  T Ulusu; H Bodur; M E Odabaş
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

3.  Radiopacity of dental restorative materials.

Authors:  Tomaž Hitij; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2012-07-24       Impact factor: 3.573

4.  Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth.

Authors:  Francisco Haiter-Neto; Andrea dos Anjos Pontual; Morten Frydenberg; Ann Wenzel
Journal:  Clin Oral Investig       Date:  2008-01-22       Impact factor: 3.573

5.  Evaluation of Cone Beam Computed Tomography (CBCT) System: Comparison with Intraoral Periapical Radiography in Proximal Caries Detection.

Authors:  Solmaz Valizadeh; Mohammad Amin Tavakkoli; Homaoun Karimi Vasigh; Zeynab Azizi; Tara Zarrabian
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-03-13

6.  Current status of dental caries diagnosis using cone beam computed tomography.

Authors:  Young-Seok Park; Jin-Soo Ahn; Ho-Beom Kwon; Seung-Pyo Lee
Journal:  Imaging Sci Dent       Date:  2011-06-23

Review 7.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

8.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.