Effect of different location of atrial lead position on nearfield and farfield electrograms in dual chamber pacemaker-defibrillators.

B K Kantharia1, S L Wilbur, F A Padder, J C Pennington , F L Samuels, C M Movsowitz, S E Hessen, C Saari, S P Kutalek.   

Abstract

The normal functioning of dual chamber pacemaker-cardioverter defibrillator (AV pacer/ICD) may be affected by oversensing of the farfield R wave (FFRW) by the atrial channel. This study aimed to investigate whether placement of the AV pacer/ICD's atrial lead at a lateral (LAT) wall location compared to a medial (MED) location i.e. the appendage of the right atrium, would reduce the amplitude of FFRWs but not the nearfield atrial electrograms (AEGMs) during sinus rhythm (SR) and ventricular fibrillation (VF). In 17 patients, real time electrograms were recorded during SR and induced VF through the atrial lead initially at the MED and subsequently at the LAT location. In 10 patients the electrograms in SR were also recorded on a computerized data acquisition and recording system at different band-pass filter settings. Although FFRWs were recorded both at MED and LAT locations, they were much smaller, 3.5+/-4.1mm during SR and 1.7+/-2.2mm during VF at the LAT location. At 30-500Hz band-pass filter, lower amplitudes of FFRWs 0.14+/-0.09 mV were recorded at the LAT location. The V/A ratios of the amplitudes of FFRWs and AEGMs were smaller at the LAT location during SR and VF. The nearfield AEGMs were of similar amplitudes at the MED and LAT locations. These data indicate that lower amplitudes of FFRWs are recorded by placement of the atrial lead at the lateral wall of the right atrium. Oversensing of FFRWs may be prevented to improve functioning of the AV pacer-ICD.

Entities:  

Mesh:

Year:  2001        PMID: 11248775     DOI: 10.1023/a:1009805807837

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  11 in total

1.  Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?

Authors:  B Nowak; B Kramm; H Schwaier; A Maimaitiming; S Geil; C Zellerhoff; O Przibille; S Rosocha; A Liebrich; J Meyer
Journal:  Pacing Clin Electrophysiol       Date:  1998-11       Impact factor: 1.976

2.  Utility of the atrial endocardial electrogram concurrent with dual-chamber pacing in the determination of a pacemaker-mediated arrhythmia.

Authors:  A H Shandling; M J Castellanet; J C Messenger; R R Brownlee
Journal:  Pacing Clin Electrophysiol       Date:  1988-10       Impact factor: 1.976

3.  Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing.

Authors:  J Brandt; T Fåhraeus; H Schüller
Journal:  Pacing Clin Electrophysiol       Date:  1988-10       Impact factor: 1.976

4.  Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing.

Authors:  J Brandt; T Fåhraeus; H Schüller
Journal:  Pacing Clin Electrophysiol       Date:  1988-11       Impact factor: 1.976

5.  Characteristics of intracardiac electrograms II: Atrial endocardial electrograms.

Authors:  V Parsonnet; G H Myers; Y M Kresh
Journal:  Pacing Clin Electrophysiol       Date:  1980-07       Impact factor: 1.976

6.  The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers.

Authors:  G C Timmis; D C Westveer; G Gadowski; J R Stewart; S Gordon
Journal:  Am Heart J       Date:  1984-10       Impact factor: 4.749

7.  Correlation between the ventricular electrogram amplitude in sinus rhythm and in ventricular fibrillation.

Authors:  J W Leitch; R Yee; G J Klein; D L Jones; C J Murdock
Journal:  Pacing Clin Electrophysiol       Date:  1990-09       Impact factor: 1.976

8.  Electrical proarrhythmia: induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator.

Authors:  C Wolpert; W Jung; C Scholl; S Spehl; J Cyran; B Lüderitz
Journal:  J Cardiovasc Electrophysiol       Date:  1998-08

9.  Sensing characteristics of the right atrial appendage electrode.

Authors:  J C Griffin
Journal:  Pacing Clin Electrophysiol       Date:  1983-01       Impact factor: 1.976

10.  Measurement of ventricular electrogram amplitude during intraoperative induction of ventricular tachyarrhythmias.

Authors:  K A Ellenbogen; M A Wood; B S Stambler; W J Welch; R J Damiano
Journal:  Am J Cardiol       Date:  1992-10-15       Impact factor: 2.778

View more
  2 in total

Review 1.  Algorithms for better arrhythmia discrimination in implantable cardioverter defibrillators.

Authors:  R Schimpf; C Wolpert; B Lüderitz
Journal:  Curr Cardiol Rep       Date:  2001-11       Impact factor: 2.931

Review 2.  The role of pacing in rhythm control and management of atrial fibrillation.

Authors:  John Silberbauer; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2007-05-02       Impact factor: 1.759

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.