Literature DB >> 11242273

Thoracic pedicle: surgical anatomic evaluation and relations.

H C Ugur1, A Attar, A Uz, I Tekdemir, N Egemen, Y Genç.   

Abstract

This anatomic study investigated the thoracic pedicle and its relations. The objective was to emphasize the importance of the thoracic pedicle for transpedicular screw fixation to avoid complications during surgery. Twenty cadavers were used to observe the cervical pedicle and its relations. The isthmus of the pedicle was exposed after removal of whole-posterior bony elements, including spinous processes, laminas, lateral masses, and the inferior and superior facets. The pedicle width and height, interpedicular distance, pedicle-inferior nerve root distance, pedicle-superior nerve root distance, pedicle-dural sac distance, root exit angle, and nerve root diameter were measured. There was no distance between the pedicle and dural sac in eight specimens. There was, however, a short distance in 12 remaining specimens in the upper and lower thoracic regions. The distances between the thoracic pedicle and the adjacent nerve roots ranged from 1.5 to 6.7 mm and 0.8 to 6.0 mm superiorly and inferiorly at all levels. The mean pedicle height and width at T1-T12 ranged from 2.9 to 11.4 mm and 6.2 to 21.3 mm, respectively. The interpedicular distance decreased gradually from T1 to T5 and then increased gradually to T12. The mean root exit angle decreased consistently from 104 degrees to 60 degrees. The nerve root diameter was between 2.3 and 2.5 mm at the T1-T5 level and then increased consistently from 2.5 to 3.7 mm. All significant differences were noted at p < 0.05 and p < 0.01. The following suggestions are made based on these results. 1) More care should be taken when a transpedicular screw is placed in the horizontal plane. 2) Improper medial placement of the pedicle screw, especially in the middle thoracic spine, should be avoided, and the anatomic variations between individuals should be considered. 3) Because of substantial variations in the size of thoracic pedicles, utmost attention should be given to the findings of a computed tomographic evaluation before thoracic transpedicular fixation is begun.

Mesh:

Year:  2001        PMID: 11242273     DOI: 10.1097/00002517-200102000-00007

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  27 in total

1.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2010-09-17       Impact factor: 1.246

3.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

4.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

5.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

6.  Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?

Authors:  Serkan Erkan; Brian Hsu; Chunhui Wu; Amir A Mehbod; John Perl; Ensor E Transfeldt
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

7.  Pedicle morphometry for thoracic screw fixation in ethnic koreans : radiological assessment using computed tomographic myelography.

Authors:  Yong Soo Choi; Young Jin Kim; Hyeong-Joong Yi; Young-Joon Kim
Journal:  J Korean Neurosurg Soc       Date:  2009-10-31

8.  Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

Authors:  Ignacio Regidor; Gema de Blas; Carlos Barrios; Jesús Burgos; Elena Montes; Sergio García-Urquiza; Edurado Hevia
Journal:  Eur Spine J       Date:  2011-04-22       Impact factor: 3.134

9.  Transforaminal Thoracic Interbody Fusion (TTIF) for Treatment of a Chronic Chance Injury.

Authors:  Russel C Huang; Dennis S Meredith; Raja Taunk
Journal:  HSS J       Date:  2009-10-16

10.  Pedicle morphometry in patients with adolescent idiopathic scoliosis.

Authors:  Bidre Upendra; Devkant Meena; Pankaj Kandwal; Abrar Ahmed; Buddhadev Chowdhury; Arvind Jayaswal
Journal:  Indian J Orthop       Date:  2010-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.