Literature DB >> 11241814

3D contrast-enhanced MR angiography of the run-off vessels: value of image subtraction.

S G Ruehm1, D Nanz, A Baumann, M Schmid, J F Debatin.   

Abstract

The diagnostic gain associated with image subtractions was assessed regarding contrast-enhanced 3D magnetic resonance angiography (MRA) image sets of the pelvic and lower extremity arteries. The MRA strategy combined a dedicated vascular coil with a single injection, two-station protocol. Voxel-by-voxel signal intensity subtraction was performed on MRA image sets obtained before and during dynamic infusion of a para-magnetic contrast agent. Non-subtracted and subtracted MRA image sets were assessed for the presence of occlusive (four grades) disease, using DSA as the standard of reference. In addition, SNR and CNR were recorded for each vascular segment on both the non-subtracted and subtracted images. While CNR values of subtracted images exceeded those of non-subtracted images (P < 0.05), there was no difference in diagnostic performance. For the detection of hemodynamically significant disease, non-subtracted and subtracted MRA provided overall sensitivity and specificity of 90.2%/90.3% and 95.1%/95.6%, respectively. Concordance between non-subtracted and subtracted MRA was excellent (Kappa = 0.86).

Mesh:

Substances:

Year:  2001        PMID: 11241814     DOI: 10.1002/jmri.1058

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Fusion and subtraction post-processing in body MRI.

Authors:  Tom A Watson; Øystein E Olsen
Journal:  Pediatr Radiol       Date:  2014-09-02

Review 2.  Introduction to Cardiovascular Magnetic Resonance: Technical Principles and Clinical Applications.

Authors:  Wen-Yih Isaac Tseng; Mao-Yuan Marine Su; Yao-Hui Elton Tseng
Journal:  Acta Cardiol Sin       Date:  2016-03       Impact factor: 2.672

3.  Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography.

Authors:  Annette Hentsch; Manuela A Aschauer; Jörn O Balzer; Joachim Brossmann; Hans P Busch; Kirsten Davis; Philippe Douek; Franz Ebner; Jos M A van Engelshoven; Michaela Gregor; Christian Kersting; Patrick R Knüsel; Edward Leen; Tim Leiner; Christian Loewe; Simon McPherson; Peter Reimer; Fritz K W Schäfer; Matthias Taupitz; Siegfried A Thurnher; Bernd Tombach; Robin Wegener; Dominik Weishaupt; James F M Meaney
Journal:  Eur Radiol       Date:  2003-03-25       Impact factor: 5.315

Review 4.  [Nephrogenic systemic fibrosis (NSF)--implications for radiology].

Authors:  H J Michaely; H S Thomsen; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2007-09       Impact factor: 0.635

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.