Literature DB >> 11241807

Global myocardial blood flow and global flow reserve measurements by MRI and PET are comparable.

J W Koskenvuo1, H Sakuma, P Niemi, J O Toikka, J Knuuti, H Laine, M Komu, M Kormano, M Saraste, J J Hartiala.   

Abstract

Coronary flow reserve (CFR) measurements have been widely used in assessing the functional significance of coronary artery stenosis because they are more sensitive in predicting major cardiac events than angiographically detected reductions of coronary arteries. Myocardial blood flow can be determined by measuring coronary sinus (CS) flow with velocity-encoded cine magnetic resonance imaging (VEC-MRI). The purpose of this study was to compare global myocardial blood flow (MBF) and CFR measured using VEC-MRI with MBF and CFR measured using positron emission tomography (PET). We measured MBF at baseline and after dipyridamole-induced hyperemia in 12 male volunteers with VEC-MRI and PET. With VEC-MRI, MBF was 0.64 +/- 0.09 (ml/min/g) at baseline and 1.59 +/- 0.79 (ml/min/g) at hyperemia, which yielded an average CFR of 2.51 +/- 1.29. With PET, MBF was 0.65 +/- 0.20 (ml/min/g) at baseline and 1.78 +/- 0.72 (ml/min/g) at hyperemia, which yielded an average CFR of 2.79 +/- 0.97. The correlation of MBFs between these two methods was good (r = 0.82, P < 0.001). The CFRs measured by MRI correlated well with those measured using PET (r = 0.76, P < 0.004). These results suggest that MRI is a useful and accurate method to measure global MBF and CFR. Therefore, it would be suitable for studying risk factor modifications of vascular function at an early stage in healthy volunteers.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11241807     DOI: 10.1002/jmri.1051

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

1.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

2.  Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches.

Authors:  Giovanni Storto; Andrea Soricelli; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

3.  Measurement of coronary flow reserve by noninvasive cardiac imaging.

Authors:  Alberto Cuocolo; Mario Petretta; Andrea Soricelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06       Impact factor: 9.236

4.  "Myocardial transit-time" (MyoTT): a novel and easy-to-perform CMR parameter to assess microvascular disease.

Authors:  Grigorios Chatzantonis; Michael Bietenbeck; Anca Florian; Claudia Meier; Dennis Korthals; Holger Reinecke; Ali Yilmaz
Journal:  Clin Res Cardiol       Date:  2019-07-18       Impact factor: 5.460

Review 5.  Diagnosis and management of coronary allograft vasculopathy in children and adolescents.

Authors:  Nathalie Dedieu; Gerald Greil; James Wong; Matthew Fenton; Michael Burch; Tarique Hussain
Journal:  World J Transplant       Date:  2014-12-24

6.  Functional cardiac magnetic resonance imaging (MRI) in the assessment of myocardial viability and perfusion: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2003-11-01

7.  A fast and effective method of quantifying myocardial perfusion by magnetic resonance imaging.

Authors:  Giovanni Donato Aquaro; Giancarlo Todiere; Gianluca Di Bella; Letizia Guiducci; Alessandro Pingitore; Vincenzo Lionetti
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-21       Impact factor: 2.357

Review 8.  Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers.

Authors:  Mario Petretta; Andrea Soricelli; Giovanni Storto; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2008 May-Jun       Impact factor: 5.952

9.  Reduced global myocardial perfusion reserve in DCM and HCM patients assessed by CMR-based velocity-encoded coronary sinus flow measurements and first-pass perfusion imaging.

Authors:  Michael Bietenbeck; Anca Florian; Zornitsa Shomanova; Claudia Meier; Ali Yilmaz
Journal:  Clin Res Cardiol       Date:  2018-05-17       Impact factor: 5.460

10.  Gender differences in response to cold pressor test assessed with velocity-encoded cardiovascular magnetic resonance of the coronary sinus.

Authors:  Pierre-Julien Moro; Antonin Flavian; Alexis Jacquier; Frank Kober; Jacques Quilici; Bénédicte Gaborit; Jean-Louis Bonnet; Guy Moulin; Patrick J Cozzone; Monique Bernard
Journal:  J Cardiovasc Magn Reson       Date:  2011-09-23       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.