Literature DB >> 11241119

Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis.

T Ohki1, J Parodi, F J Veith, M Bates, M Bade, D Chang, M Mehta, J Rabin, K Goldstein, J Harvey, E Lipsitz.   

Abstract

OBJECTIVE: The role of percutaneous angioplasty and stenting of carotid bifurcation lesions has been limited by its potential for producing embolic debris. We evaluated the efficacy of a proximal occlusion catheter (POC) in the prevention of embolic events during carotid artery stenting. In addition, pressure measurements relevant to the clinical application of this device were obtained from 10 patients undergoing carotid endarterectomy.
METHODS: The POC is a guiding catheter with an occlusion balloon attached on the outside of the catheter at its distal end. Occlusion of the common carotid artery (CCA) was achieved by inflating the balloon while access to carotid bifurcation lesions was obtained through the inner lumen. The POC was inserted in the CCA of 10 dogs via the femoral artery. The side port of the POC was connected to a sheath placed in the femoral vein, thereby creating an external arteriovenous shunt. Ten artificial radiopaque particles simulating embolic particles and contrast agent were introduced in the CCA and monitored fluoroscopically. As a control, the same procedure was performed with a standard guiding catheter without an occlusion balloon. In 10 patients undergoing carotid endarterectomy, the internal carotid artery (ICA) and external carotid artery stump pressures and the pressure in the internal jugular vein were measured.
RESULTS: Without the external arteriovenous shunt, in all animals there was prograde flow in the distal CCA despite CCA occlusion. This flow was derived from the thyroid artery. However, once the arteriovenous shunt was activated, reversal of flow in the distal CCA was achieved in each animal, and all the artificial particles were recovered from the side port of the POC. In the control group, each particle embolized to the brain (100%, P <.01). In the patients, the mean stump pressures in the ICA and external carotid artery and the jugular vein pressure were 51.8 +/- 14.2, 62.2 +/- 15.1, and 6.5 +/- 3.5 mm Hg, respectively. In each case, the jugular vein pressure was the lowest among the three.
CONCLUSIONS: Obtaining proximal CCA control by inflating the POC does not sufficiently prevent embolization. However, reversal of flow in the ICA can always be created with the external shunt, which effectively prevents embolization. Thus, POC may markedly lower procedural stroke rates during carotid artery stenting. The ability of POC to prevent embolization before crossing the lesion with a guidewire may be an important advantage over other distal protection devices.

Entities:  

Mesh:

Year:  2001        PMID: 11241119     DOI: 10.1067/mva.2001.112278

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Treatment of cervical carotid artery stenosis.

Authors:  S Yoshimura
Journal:  Interv Neuroradiol       Date:  2008-05-15       Impact factor: 1.610

2.  Successful carotid stenting for chronic total occlusion of the internal carotid artery.

Authors:  Won Ho Kim; Pil-Ki Min; Dong Jun Kim; Won-Heum Shim
Journal:  Korean Circ J       Date:  2010-06-29       Impact factor: 3.243

3.  Carotid artery stenting for stenosis with intraluminal thrombus.

Authors:  Tomoyuki Tsumoto; Tomoaki Terada; Mitsuharu Tsuura; Hiroyuki Matsumoto; Osamu Masuo; Hiroo Yamaga; Toru Itakura
Journal:  Neuroradiology       Date:  2005-10-21       Impact factor: 2.804

4.  Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note.

Authors:  Nozomu Kobayashi; Shigeru Miyachi; Kenichi Hattori; Toshihiko Tanasawa; Takeshi Okada; Otone Endo; Naohito Yamamoto
Journal:  Neuroradiology       Date:  2006-08-10       Impact factor: 2.804

5.  [Carotid artery stenting technique].

Authors:  J Schofer; K Bijuklic
Journal:  Herz       Date:  2013-11       Impact factor: 1.443

6.  Cerebral ischemia detected with diffusion-weighted MR imaging after protected carotid artery stenting: comparison of distal balloon and filter device.

Authors:  Suk Jung Kim; Hong Gee Roh; Pyoung Jeon; Keon Ha Kim; Kwang Ho Lee; Hong Sik Byun; Won Jin Moon; Gyeong Moon Kim; Young Wook Kim; Dong Ik Kim
Journal:  Korean J Radiol       Date:  2007 Jul-Aug       Impact factor: 3.500

7.  Distal protection devices during percutaneous coronary and carotid interventions.

Authors:  Panayotis Fasseas; James L Orford; Ali E Denktas; Peter B Berger
Journal:  Curr Control Trials Cardiovasc Med       Date:  2001

8.  Cerebral monitoring during transcarotid artery revascularization with flow reversal via transcranial doppler ultrasound examination.

Authors:  Lindsey A Olivere; James Ronald; Zachary Williams; Mitchell W Cox; Chandler Long; Cynthia K Shortell; Kevin W Southerland
Journal:  J Vasc Surg       Date:  2020-04-22       Impact factor: 4.268

9.  Predictors of Successful First-Pass Thrombectomy with a Balloon Guide Catheter: Results of a Decision Tree Analysis.

Authors:  Aglaé Velasco Gonzalez; Dennis Görlich; Boris Buerke; Nico Münnich; Cristina Sauerland; Thilo Rusche; Andreas Faldum; Walter Heindel
Journal:  Transl Stroke Res       Date:  2020-05-23       Impact factor: 6.800

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.