Literature DB >> 11239590

Association between microtensile bond strength and leakage in the indirect resin composite/dentin adhesively bonded joint.

S Guzmán-Ruiz1, S R Armstrong, D S Cobb, M A Vargas.   

Abstract

PURPOSE: Develop a methodology to correlate microtensile bond strength (microTBS) and leakage within the same site of a specimen and evaluate the predominate debond and leakage pathways.
MATERIALS AND METHODS: A Class II (MO) slot cavity was prepared in 37 extracted human molars and restored with indirect resin composite restorations. The restored teeth were thermocycled 300X between 5 and 55 degrees C and then stained with silver. Two specimens per tooth were obtained by diamond saw sectioning for measurement of leakage (microm) and microtensile bond strength (MPa) at the gingival wall and then tested for association with regression analysis. Scanning electron microscopy techniques and energy dispersive spectroscopy (EDS) were used to evaluate the debond and leakage pathways.
RESULTS: Association between leakage and bond strength was not significant (t=1.31, p=0.198). All 74 samples debonded within the joint, predominantly at the hybrid layer-adhesive resin region with only one specimen including a small portion of resin cement in the debond pathway. Secondary and backscatter imaging and EDS analysis showed leakage in all samples that involved the hybrid layer.
CONCLUSION: This study demonstrates a feasible method for evaluating leakage and bond strength at the joint interface within the same specimen.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11239590     DOI: 10.1016/s0300-5712(00)00065-8

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  5 in total

1.  Bonding and sealing ability of a new self-adhering flowable composite resin in class I restorations.

Authors:  Alessandro Vichi; Mariam Margvelashvili; Cecilia Goracci; Federica Papacchini; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2012-10-20       Impact factor: 3.573

2.  A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion - An ex vivo study.

Authors:  Ankit Arora; Shashi Rashmi Acharya; Saraswathi M Vidya; Padmaja Sharma
Journal:  Contemp Clin Dent       Date:  2012-07

3.  Effect of resin coating and chlorhexidine on microleakage of two resin cements after storage.

Authors:  F Shafie; M Doozandeh; A Alavi
Journal:  J Dent (Tehran)       Date:  2010-03-31

4.  Effect of Chlorhexidine Application Protocol on Durability of Marginal Seal of Class V Restorations.

Authors:  Anna Saffarpour; Aida Saffarpour; Mohammad Javad Kharazifard; Atoussa Entezami Rad
Journal:  J Dent (Tehran)       Date:  2016-08

5.  Comparison of microleakage between bulk-fill flowable and nanofilled resin-based composites.

Authors:  Eman I AlSagob; David N Bardwell; Ala O Ali; Samer G Khayat; Paul C Stark
Journal:  Interv Med Appl Sci       Date:  2018-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.