Literature DB >> 11219081

Thiosalicylic acid-immobilized Amberlite XAD-2: metal sorption behaviour and applications in estimation of metal ions by flame atomic absorption spectrometry.

P K Tewari1, A K Singh.   

Abstract

Thiosalicylic acid (TSA)-modified Amberlite XAD-2 (AXAD-2) was synthesized by coupling TSA with the support matrix AXAD-2 through an azo spacer. The resulting chelating resin was characterized by elemental analyses, thermogravimetric analysis (TGA) and infrared spectra. The newly designed resin quantitatively sorbs CdII, CoII, CuII, FeIII, NiII and ZnII at pH 3.5-7.0 when the flow rate is maintained between 2 and 4 ml min-1. The HCl or HNO3 (2 mol l-1) instantaneously elutes all the metal ions. The sorption capacity is 197.5, 106.9, 214.0, 66.2, 309.9 and 47.4 mumol g-1 of the resin for cadmium, cobalt, copper, iron, nickel and zinc, respectively, whereas their preconcentration factor is between 180-400. The breakthrough volume of HCl or HNO3 for elution of these metal ions was found to be 4-8 ml. The limit of detection (LOD) for CdII, CoII, CuII, FeIII, NiII and ZnII was 0.48, 0.20, 4.05, 0.98, 1.28 and 3.94 micrograms l-1, respectively, and the limit of quantification (LOQ) was found to be 0.51, 0.29, 4.49, 1.43, 1.58 and 4.46 micrograms l-1, respectively. The loading half time, t1/2, for the cations was found to be less than 2.0 min, except for nickel for which the value was 13.1 min. The determination of each of these six cations is possible in the presence of other five, if their concentration is up to 4 times. All six metals were determined in river water (RSD approximately 0.7-7.7%) and tap water samples (RSD approximately 0.3-5.7%). The estimation of Co was made in the samples of multivitamin tablets (RSD < 2.3%). The results agree with those quoted by manufacturers.

Entities:  

Year:  2000        PMID: 11219081     DOI: 10.1039/b006788l

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  7 in total

1.  An online preconcentration system for the determination of uranium in water and effluent samples.

Authors:  Valfredo Azevedo Lemos; Ednilton Moreira Gama
Journal:  Environ Monit Assess       Date:  2009-12-16       Impact factor: 2.513

2.  Preconcentration of metal ions through chelation on a synthesized resin containing O, O donor atoms for quantitative analysis of environmental and biological samples.

Authors:  Aminul Islam; Mohammad Asaduddin Laskar; Akil Ahmad
Journal:  Environ Monit Assess       Date:  2012-07-19       Impact factor: 2.513

3.  A Ratiomeric Fluorescent Sensor for Zn2+ Based on N,N'-Di(quinolin-8-yl)oxalamide.

Authors:  Fashuo Yu; Xiangfeng Guo; Xiujuan Tian; Lihua Jia
Journal:  J Fluoresc       Date:  2016-12-21       Impact factor: 2.217

4.  A quick accelerating microwave-assisted sustainable technique: permutated spiro-casing for imaging experiment.

Authors:  Animesh Mondal; Barnali Naskar; Sanchita Goswami; Chandraday Prodhan; Keya Chaudhuri; Chhanda Mukhopadhyay
Journal:  Mol Divers       Date:  2019-03-06       Impact factor: 2.943

5.  A 2-Hydroxy-1-naphthaldehyde Schiff Base for Turn-on Fluorescence Detection of Zn2+ Based on PET Mechanism.

Authors:  Xinyue Mu; Liping Shi; Liqiang Yan; Ningli Tang
Journal:  J Fluoresc       Date:  2021-04-16       Impact factor: 2.217

6.  Stability of antibiotics in drinking water: An advanced approach towards the impacts of water quality parameters on doxycycline bioavailability.

Authors:  Saber Kotb; Moustafa Ahmed; Dalia Hassan; Esraa Soltan
Journal:  J Adv Vet Anim Res       Date:  2019-09-09

7.  Synthesis and application of Amberlite xad-4 functionalized with alizarin red-s for preconcentration and adsorption of rhodium (III).

Authors:  Hossein Sid Kalal; Homayon Ahmad Panahi; Hassan Hoveidi; Mohammad Taghiof; Mahnaz Taheri Menderjani
Journal:  Iranian J Environ Health Sci Eng       Date:  2012-09-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.