A fast method for calibrating video-based motion analysers using only a rigid bar.

N A Borghese1, P Cerveri, P Rigiroli.   

Abstract

Video-camera systems are widely used in biomechanics and clinical fields to measure the 3D kinematic measurements of human motion. To be used, they need to be calibrated, that is the parameters which geometrically define the cameras have to be determined. It is shown here how this can be achieved by surveying a rigid bar in motion inside the working volume, and in a very short time: less than 15 s on a Pentium III. The exterior parameters are estimated through the coplanarity constraint, the camera focal lengths through the properties of epipolar geometry and the principal points with a fast evolutionary optimisation which guarantees convergence when the initial principal points cannot be adequately estimated. The method has been widely tested on simulated and real data. Results show that its accuracy is comparable with that obtained using methods based on points of known 3D coordinates (DLT): 0.37 mm RMS error over a volume with a diagonal approximately 1.5 m. A preferential absolute reference system is obtained from the same bar motion data and is used to guide an intelligent decimation of the data. Finally, the role that the principal points play in achieving a high accuracy, which is questioned in the computer vision domain, is assessed through simulations.

Entities:  

Mesh:

Year:  2001        PMID: 11214276     DOI: 10.1007/bf02345269

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  5 in total

1.  Accuracy assessment and control point configuration when using the DLT for photogrammetry.

Authors:  J H Challis; D G Kerwin
Journal:  J Biomech       Date:  1992-09       Impact factor: 2.712

2.  An algorithm for 3-D automatic movement detection by means of standard TV cameras.

Authors:  N A Borghese; G Ferrigno
Journal:  IEEE Trans Biomed Eng       Date:  1990-12       Impact factor: 4.538

3.  Complete calibration of a stereo photogrammetric system through control points of unknown coordinates.

Authors:  P Cerveri; N A Borghese; A Pedotti
Journal:  J Biomech       Date:  1998-10       Impact factor: 2.712

4.  Statistical comparison of DLT versus ILSSC in the calibration of a photogrammetric stereo-system.

Authors:  N A Borghese; P Cerveri; G C Ferrigno
Journal:  J Biomech       Date:  1997-04       Impact factor: 2.712

5.  Three-dimensional cinematography with control object of unknown shape.

Authors:  J Dapena; E A Harman; J A Miller
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

  5 in total
  1 in total

1.  Normative 3D opto-electronic stereo-photogrammetric posture and spine morphology data in young healthy adult population.

Authors:  Moreno D'Amico; Edyta Kinel; Piero Roncoletta
Journal:  PLoS One       Date:  2017-06-22       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.