Literature DB >> 11214275

Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics.

P Bifulco1, M Cesarelli, R Allen, M Sansone, M Bracale.   

Abstract

Intervertebral kinematics closely relates to the functionality of the spinal segments. Direct measurement of the intervertebral kinematics in vivo is very problematic. The use of a fluoroscopic device can provide continuous screening of the lumbar tract during patient spontaneous motion, with an acceptable, low X-ray dose. The kinematic analysis is intended to be limited to planar motion. Kinematic parameters are computed from vertebral landmarks on each frame of the image sequence. Landmarks are normally selected manually in spite of the fact that this is subjective, tedious to perform and regarded as one of the major contributors to errors in the computed kinematic parameters. The aim of this work is to present an innovative method for the automatic recognition of vertebral landmarks throughout a fluoroscopic image sequence to provide an objective and more precise quantification of intervertebral kinematics. The recognition procedure is based upon comparing vertebral features in two adjacent frames by means of a cross-correlation index, which is also robust despite the low signal-to-noise ratio of the lumbar fluoroscopic images. To provide a quantitative assessment of this method a calibration model was used which consisted of two lumbar vertebrae linked by a universal joint. The reliability and accuracy of the kinematic measurements have been investigated. The errors are of the order of a millimetre for the localisation of the intervertebral centre of rotation and tenths of a degree for the intervertebral angle. Error analysis suggests that this method improves the accuracy of the intervertebral kinematic calculations and has the potential to automate the selection of anatomical landmarks.

Entities:  

Mesh:

Year:  2001        PMID: 11214275     DOI: 10.1007/bf02345268

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

1.  Lumbar posterior ligament involvement during extremely heavy lifts estimated from fluoroscopic measurements.

Authors:  J Cholewicki; S M McGill
Journal:  J Biomech       Date:  1992-01       Impact factor: 2.712

2.  Method for measuring vertebral kinematics from videofluoroscopy.

Authors:  J Cholewicki; S M McGill; R P Wells; H Vernon
Journal:  Clin Biomech (Bristol, Avon)       Date:  1991-05       Impact factor: 2.063

3.  Cervical spine motion in the sagittal plane (I) range of motion of actually performed movements, an X-ray cinematographic study.

Authors:  H Van Mameren; J Drukker; H Sanches; J Beursgens
Journal:  Eur J Morphol       Date:  1990

4.  Spinal analysis using a three-dimensional radiographic technique.

Authors:  R H Brown; A H Burstein; C L Nash; C C Schock
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

5.  A new technique for measuring lumbar segmental motion in vivo. Method, accuracy, and preliminary results.

Authors:  T Steffen; R K Rubin; H G Baramki; J Antoniou; D Marchesi; M Aebi
Journal:  Spine (Phila Pa 1976)       Date:  1997-01-15       Impact factor: 3.468

6.  Instantaneous axes of rotation of the lumbar intervertebral joints.

Authors:  M J Pearcy; N Bogduk
Journal:  Spine (Phila Pa 1976)       Date:  1988-09       Impact factor: 3.468

7.  Measurement of the total motion between two body segments. I. Analytical development.

Authors:  G L Kinzel; A S Hall; B M Hillberry
Journal:  J Biomech       Date:  1972-01       Impact factor: 2.712

8.  Three-dimensional mathematical model of the human spine structure.

Authors:  M M Panjabi
Journal:  J Biomech       Date:  1973-11       Impact factor: 2.712

9.  Centers and angles of rotation of body joints: a study of errors and optimization.

Authors:  M M Panjabi
Journal:  J Biomech       Date:  1979       Impact factor: 2.712

10.  Radiographic studies of lateral flexion in the lumbar spine.

Authors:  J Dimnet; L P Fischer; G Gonon; J P Carret
Journal:  J Biomech       Date:  1978       Impact factor: 2.712

View more
  3 in total

1.  Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Authors:  Giacomo Tarroni; Luca Tersi; Cristiana Corsi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-03-27       Impact factor: 2.602

2.  X-ray fluoroscopy noise modeling for filter design.

Authors:  M Cesarelli; P Bifulco; T Cerciello; M Romano; L Paura
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-21       Impact factor: 2.924

3.  Measurement of intervertebral cervical motion by means of dynamic x-ray image processing and data interpolation.

Authors:  Paolo Bifulco; Mario Cesarelli; Maria Romano; Antonio Fratini; Mario Sansone
Journal:  Int J Biomed Imaging       Date:  2013-10-31
  3 in total