Literature DB >> 11207466

Reduced isoflurane consumption with bispectral index monitoring.

B Guignard1, C Coste, C Menigaux, M Chauvin.   

Abstract

BACKGROUND: Bispectral index (BIS) monitoring has been found to decrease the requirements for propofol, sevoflurane and desflurane and to improve recovery. We wanted to assess the effect of BIS monitoring on intraoperative isoflurane utilisation, and the early recovery profile.
METHODS: Eighty patients undergoing various surgical procedures were studied. In the first phase of the study, patients were anaesthetised without the use of BIS, the anaesthetists being blinded to the BIS readings, and isoflurane being administered according to standard clinical practice (control group). In a second phase, isoflurane was titrated to maintain a BIS value between 40 and 60 during surgery, and then 60-70 during 15 min prior to the end of surgery (BIS group). Isoflurane consumption was measured. Recovery times and the time to achieve a modified Aldrete score of 9 were recorded.
RESULTS: Despite similar mean BIS levels during maintenance of anaesthesia, the cumulative time spent with BIS values between 40 and 60 during maintenance of anaesthesia was significantly longer in the BIS group as compared with the control group (P<0.001). The isoflurane usage in the BIS group was 12-25% lower than in the control group (P<0.05). The time to awakening and extubation were comparable in the two groups. Although the patients were less sedated (P<0.01) during the three postoperative hours in the BIS (vs. control) group, no significant differences were observed in the time to obtain an Aldrete score of 9.
CONCLUSION: The addition of BIS to standard monitoring decreases isoflurane consumption. However, we found only a small advantage in using BIS with respect to recovery from isoflurane anaesthesia.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11207466     DOI: 10.1034/j.1399-6576.2001.045003308.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  6 in total

Review 1.  Using EEG to monitor anesthesia drug effects during surgery.

Authors:  Leslie C Jameson; Tod B Sloan
Journal:  J Clin Monit Comput       Date:  2006-12       Impact factor: 2.502

2.  Comparison of the EEG-based SNAP index and the Bispectral (BIS) index during sevoflurane-nitrous oxide anaesthesia.

Authors:  P Ruiz-Gimeno; M Soro; A Pérez-Solaz; M Carrau; F J Belda; J L Jover; G Aguilar
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

Review 3.  Bispectral index for improving anaesthetic delivery and postoperative recovery.

Authors:  Yodying Punjasawadwong; Aram Phongchiewboon; Nutchanart Bunchungmongkol
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

4.  Bispectral index monitor: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2004-06-01

Review 5.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18

6.  Effect of bispectral index monitoring on desflurane consumption and recovery time in morbidly obese patients undergoing laparoscopic sleeve gastrectomy.

Authors:  Tamer H Ibrahim; Gamal T Yousef; Ali M Ali Hasan; Hossam I Eldesuky
Journal:  Anesth Essays Res       Date:  2013 Jan-Apr
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.