RATIONALE AND OBJECTIVES: The authors performed this study to (a) investigate coronary movement with electron-beam computed tomography (CT) and (b) find the optimal electrocardiographic (ECG) triggering phase for eliminating motion artifact. MATERIALS AND METHODS: One hundred fifty-one patients without arrhythmia were examined with electron-beam CT. First, movie scans were obtained to create displacement and velocity graphs of coronary artery movement. Then, a volume scan with an exposure time of 100 msec was obtained with various ECG trigger settings. RESULTS: Movement patterns of coronary arteries varied with heart rate. Optimal triggering phase was before atrial systole (near 71% of the R-R interval) when heart rate was slower than 68 beats per minute and at ventricular end systole when heart rate was fast. Rate of severe motion artifacts decreased from 43% to 0% when triggering was altered from 80% of the R-R interval to the individual optimal value. Experimental values of the optimal phase at different heart rates were derived, and severe motion artifact was only 3.0% with these values. CONCLUSION: ECG triggering set according to the heart rate enables a great reduction in motion artifacts at electron-beam CT with a 100-msec exposure time. The results may have implications for magnetic resonance imaging of the coronary artery.
RATIONALE AND OBJECTIVES: The authors performed this study to (a) investigate coronary movement with electron-beam computed tomography (CT) and (b) find the optimal electrocardiographic (ECG) triggering phase for eliminating motion artifact. MATERIALS AND METHODS: One hundred fifty-one patients without arrhythmia were examined with electron-beam CT. First, movie scans were obtained to create displacement and velocity graphs of coronary artery movement. Then, a volume scan with an exposure time of 100 msec was obtained with various ECG trigger settings. RESULTS: Movement patterns of coronary arteries varied with heart rate. Optimal triggering phase was before atrial systole (near 71% of the R-R interval) when heart rate was slower than 68 beats per minute and at ventricular end systole when heart rate was fast. Rate of severe motion artifacts decreased from 43% to 0% when triggering was altered from 80% of the R-R interval to the individual optimal value. Experimental values of the optimal phase at different heart rates were derived, and severe motion artifact was only 3.0% with these values. CONCLUSION: ECG triggering set according to the heart rate enables a great reduction in motion artifacts at electron-beam CT with a 100-msec exposure time. The results may have implications for magnetic resonance imaging of the coronary artery.
Authors: Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima Journal: Eur Radiol Date: 2008-11-08 Impact factor: 5.315