Radiochromic film dosimetry in water phantoms.

M J Butson1, T Cheung, P K Yu.   

Abstract

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate is seen from water into the film which only affects the outer areas of the film, with penetration being less than 0.5 mm per hour. The optical density measurements of the film at 660 nm remain unchanged in the unaffected regions of the radiochromic film. Minimal effects are seen due to beam orientation in a water phantom as opposed to solid water phantoms in which an overestimation in dose is normally seen for parallel irradiation. Radiochromic film seems to be an adequate detector for dosimetry in a water phantom where high spatial resolution is needed and angle of beam incidence at the point of interest is important.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11197685     DOI: 10.1088/0031-9155/46/1/405

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Measurement verification of dose distributions in pulsed-dose rate brachytherapy in breast cancer.

Authors:  Patrycja Mantaj; Grzegorz Zwierzchowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-12

2.  Dosimetry in brain tumor phantom at 15 MV 3D conformal radiation therapy.

Authors:  Larissa Thompson; Humberto Galvão Dias; Tarcísio Passos Ribeiro Campos
Journal:  Radiat Oncol       Date:  2013-07-06       Impact factor: 3.481

3.  Study of a spherical phantom for Gamma knife dosimetry.

Authors:  Dengsong Zhu; Carlos Austerlitz; Sidi Benhabib; Helvecio Mota; Ron R Allison; Diana Campos
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

4.  Investigation of EBT3 radiochromic film's response to humidity.

Authors:  Elsa Y León-Marroquín; José M Lárraga-Gutiérrez; J Alfredo Herrera-González; Miguel A Camacho-López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2018-04-29       Impact factor: 2.102

5.  Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom.

Authors:  Masao Tanooka; Hiroshi Doi; Hideharu Miura; Hiroyuki Inoue; Yasue Niwa; Yasuhiro Takada; Masayuki Fujiwara; Toshiyuki Sakai; Kiyoshi Sakamoto; Norihiko Kamikonya; Shozo Hirota
Journal:  J Radiat Res       Date:  2013-05-17       Impact factor: 2.724