Selected reaction monitoring LC-MS determination of idoxifene and its pyrrolidinone metabolite in human plasma using robotic high-throughput, sequential sample injection.

J M Onorato1, J D Henion, P M Lefebvre, J P Kiplinger.   

Abstract

The generation of large numbers of samples during early drug discovery has increased the demand for rapid and selective methods of analysis. Liquid chromatography-tandem mass spectrometry (LC-MS-MS), because of its sensitivity, selectivity, and robustness, has emerged as a powerful tool in the pharmaceutical industry for many analytical needs. This work presents a high-throughput selected reaction monitoring LC-MS bioanalytical method for the determination of idoxifene, a selective estrogen receptor modulator, and its pyrrolidinone metabolite in clinical human plasma samples. The described method uses short, small-bore columns, high flow rates, and elevated HPLC column temperatures to perform LC separations of idoxifene and its metabolite within 10 s/sample. Sequential injections were accomplished with a 215/889 multiple probe liquid handler (Gilson, Inc.), which aspirates eight samples simultaneously and performs its rinse cycle parallel to sample injection, resulting in minimum lag time between injections. This high-throughput method was applied to the determination of idoxifene and its metabolite in clinical human plasma samples. Sample preparation employed liquid/liquid extraction in the 96-well format. Method validation included determination of intra- and interassay accuracy and precision values, recovery studies, autosampler stability, and freeze-thaw stability. The LOQ obtained was 10 ng/mL for idoxifene and 30 ng/mL for the metabolite. Using idoxifene-d5 as an internal standard, idoxifene showed acceptable accuracy and precision values at QC level 1 (QC1, 15 ng/mL), level 2 (QC2, 100 ng/mL), and level 3 (QC3, 180 ng/mL) (85.0% accuracy +/- 12.0% precision, 95.1 +/- 4.9%, and 90.3 +/- 4.7%, respectively). The pyrrolidinone metabolite also showed acceptable accuracy and precision values (using no internal standard for quantitation) at QC1 (60 ng/mL), QC2 (100 ng/mL), and QC3 (180 ng/mL) (104.9 +/- 14.4%, 91.1 +/- 13.0%, and 90.8 +/- 12.2%, respectively). The validated method was applied to the analysis of 613 human clinical plasma samples. An average run time of 23 s/sample (approximately 37 min/ 96-well plate or over 3,700 sample/day) was achieved. The successful validation presented indicates that rapid methods of analysis can efficiently and reliably contribute to the fast sample turnaround required for high sample number generating processes.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11195494     DOI: 10.1021/ac000845t

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Quantitative strategies to fuel the merger of discovery and hypothesis-driven shotgun proteomics.

Authors:  Kelli G Kline; Greg L Finney; Christine C Wu
Journal:  Brief Funct Genomic Proteomic       Date:  2009-03

2.  Targeted quantitative analysis of superoxide dismutase 1 in cisplatin-sensitive and cisplatin-resistant human ovarian cancer cells.

Authors:  Jong Won Kim; Bei Nie; Heather Sahm; Dawn P G Brown; Tony Tegeler; Jin-Sam You; Mu Wang
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2010-01-18       Impact factor: 3.205

3.  Rapid detection and identification of N-acetyl-L-cysteine thioethers using constant neutral loss and theoretical multiple reaction monitoring combined with enhanced product-ion scans on a linear ion trap mass spectrometer.

Authors:  Karoline Scholz; Wolfgang Dekant; Wolfgang Völkel; Axel Pähler
Journal:  J Am Soc Mass Spectrom       Date:  2005-10-24       Impact factor: 3.109

4.  Response normalized liquid chromatography nanospray ionization mass spectrometry.

Authors:  Ragu Ramanathan; Ruyun Zhong; Neil Blumenkrantz; Swapan K Chowdhury; Kevin B Alton
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-29       Impact factor: 3.109