Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait.

P Convery1, K D Murray.   

Abstract

This study analyses the motion of the residual femur within a trans-femoral socket during gait using ultrasound data from two simultaneously transmitting transducers connected to two ultrasound scanners. Calibration tests accurately established the orientation of the two transducers mounted on the lateral wall of the socket. Relative positions of the ultrasound image of the femur were measured on video playback. Motion of the residual femur, relative to the lateral wall of the socket, at any instant during gait may be estimated, if the relative positions of the two transducers and the motion of the ultrasound image are known. A consistent pattern of femoral motion during 10 gait cycles is displayed graphically. The femoral motion in this paper is expressed as abduction/adduction or flexion/extension relative to the socket. However, without a full gait analysis study, the orientation of the socket relative to the ground or relative to the pelvis cannot be determined. Only one ultrasound scanner may be available for clinical use. Hence data collection may be restricted to only one transducer during gait. In order to simulate the single transducer mode, the ultrasound data recorded during the 10 previous gait cycles, was averaged at any instant of the gait cycle. The angular orientation of the femur was calculated based on the averaged data. Similar patterns of femoral motion were obtained irrespective of the technique adopted.

Mesh:

Year:  2000        PMID: 11195358     DOI: 10.1080/03093640008726552

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  4 in total

1.  Exploring the Use of Non-Image-Based Ultrasound to Detect the Position of the Residual Femur within a Stump.

Authors:  Sook-Yee Chong; Oliver Röhrle
Journal:  PLoS One       Date:  2016-10-20       Impact factor: 3.240

2.  Systematic Experimental Assessment of a 2D-Motion Sensor to Detect Relative Movement between Residual Limb and Prosthetic Socket.

Authors:  Veronika Noll; Stephan Rinderknecht; Philipp Beckerle
Journal:  Sensors (Basel)       Date:  2018-07-06       Impact factor: 3.576

3.  Analysis of lower limb prosthetic socket interface based on stress and motion measurements.

Authors:  Jinghua Tang; Liudi Jiang; Michael McGrath; Dan Bader; Piotr Laszczak; David Moser; Saeed Zahedi
Journal:  Proc Inst Mech Eng H       Date:  2022-07-12       Impact factor: 1.763

4.  Thorax, pelvis and hip pattern in the frontal plane during walking in unilateral transtibial amputees: biomechanical analysis.

Authors:  Francisco Molina-Rueda; Isabel M Alguacil-Diego; Alicia Cuesta-Gómez; Javier Iglesias-Giménez; Andrés Martín-Vivaldi; Juan C Miangolarra-Page
Journal:  Braz J Phys Ther       Date:  2014 May-Jun       Impact factor: 3.377

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.