Literature DB >> 11192244

In vivo kinematics of total knee arthroplasty: flat compared with concave tibial joint surface.

J Uvehammer1, J Kärrholm, S Brandsson, P Herberts, L Carlsson, J Karlsson, L Regnér.   

Abstract

This study evaluated the influence of the geometric configuration of the tibial joint area on the kinematics of the knee. Twenty-two patients with noninflammatory arthritis and minor preoperative deformity were studied. They each received an AMK total knee replacement with retention of the posterior cruciate ligament. Eleven patients without any knee abnormalities were used as controls. The patients were stratified to either the flat (terminology of the manufacturer: standard) or concave (terminology of the manufacturer: constrained) polyethylene insert (n = 11 in each group). Knee kinematics were assessed 1 year after the operation by having the patient ascend a platform corresponding to an extension of the knee from 50 to 70 degrees of flexion. During this motion, two film-exchangers simultaneously exposed six to 13 pairs of serial stereoradiographs. The concave geometric configuration of the tibial insert resulted paradoxically in increased anterior-posterior translations compared with the flat insert but no significant change of rotations and translations in the other directions. Compared with normal knees, the most obvious abnormality was increased anterior-posterior translations (p < 0.004). At 50 degrees of flexion, the implants with the flat tibial polyethylene insert had displaced 2 times and the concave ones had displaced 2.5 times more posteriorly than the normal knees (p < or = 0.001). Less internal tibial rotation was also recorded in the flexed positions for both types of inserts compared with the normal knees (p < 0.02). Four knees in four patients, who reported symptoms of instability and abnormal knee function, showed significantly increased proximal displacement of the center of the tibial plateau in the flexed position. The findings suggest that current prosthetic designs and surgical technique do not restore normal knee kinematics and indicate that design improvements should rely on in vivo kinematic studies.

Entities:  

Mesh:

Year:  2000        PMID: 11192244     DOI: 10.1002/jor.1100180603

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  14 in total

1.  The influence of tibial slope on maximal flexion after total knee arthroplasty.

Authors:  J Bellemans; F Robijns; J Duerinckx; S Banks; H Vandenneucker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-26       Impact factor: 4.342

2.  [TKA kinematics. In vivo techniques and results].

Authors:  R von Eisenhart-Rothe; T Vogl; K-H Englmeier; D A Dennis
Journal:  Orthopade       Date:  2007-07       Impact factor: 1.087

3.  Changes in knee kinematics reflect the articular geometry after arthroplasty.

Authors:  Anthony M J Bull; Oliver Kessler; Mahbub Alam; Andrew A Amis
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

4.  Predicting range of movement after knee replacement: the importance of posterior condylar offset and tibial slope.

Authors:  Ajay Malviya; E A Lingard; D J Weir; D J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-13       Impact factor: 4.342

Review 5.  Bicruciate retaining.

Authors:  Andrea Trecci
Journal:  Ann Transl Med       Date:  2016-04

6.  Tibial rotation kinematics subsequent to knee arthroplasty.

Authors:  Duane J Collins; Yasser H Khatib; David A Parker; Deanne E Jenkin; Robert B Molnar
Journal:  J Orthop       Date:  2015-01-30

7.  Assessment of posterior stability in total knee replacement by stress radiographs: prospective comparison of two different types of mobile bearing implants.

Authors:  S Louisia; R Siebold; J Canty; R J Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-04-02       Impact factor: 4.342

8.  Will early reconstruction prevent abnormal kinematics after ACL injury? Two-year follow-up using dynamic radiostereometry in 14 patients operated with hamstring autografts.

Authors:  Jonas Isberg; Eva Faxén; Gauti Laxdal; Bengt I Eriksson; Johan Kärrholm; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-18       Impact factor: 4.342

9.  [A new total knee arthroplasty with physiologically shaped surfaces. Part 2: First clinical results].

Authors:  K-H Frosch; H Nägerl; D Kubein-Meesenburg; J Buchholz; J Dörner; H Dathe; O Hellerer; C Dumont; K M Stürmer
Journal:  Unfallchirurg       Date:  2009-02       Impact factor: 1.000

10.  Total knee replacement influences both knee and hip joint kinematics during stair climbing.

Authors:  Tuuli Saari; Roy Tranberg; Roland Zügner; Johan Uvehammer; Johan Kärrholm
Journal:  Int Orthop       Date:  2004-04       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.