Literature DB >> 11192219

Evaluation of portable air samplers for monitoring airborne culturable bacteria.

S K Mehta1, D M Bell-Robinson, T O Groves, L D Stetzenbach, D L Pierson.   

Abstract

Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

Keywords:  NASA Center JSC; NASA Discipline Environmental Health

Mesh:

Year:  2000        PMID: 11192219     DOI: 10.1080/15298660008984597

Source DB:  PubMed          Journal:  AIHAJ        ISSN: 1529-8663


  4 in total

1.  Evaluation of the airborne bacterial population in the periodically confined Antarctic base Concordia.

Authors:  Rob Van Houdt; Patrick De Boever; Ilse Coninx; Claire Le Calvez; Roberto Dicasillati; Jacques Mahillon; Max Mergeay; Natalie Leys
Journal:  Microb Ecol       Date:  2008-10-30       Impact factor: 4.552

Review 2.  Dust events, pulmonary diseases and immune system.

Authors:  Nafiseh Esmaeil; Marjan Gharagozloo; Abbas Rezaei; Gabriele Grunig
Journal:  Am J Clin Exp Immunol       Date:  2014-02-27

3.  Detection of viruses in used ventilation filters from two large public buildings.

Authors:  Sagar M Goyal; Senthilvelan Anantharaman; M A Ramakrishnan; Suchitra Sajja; Seung Won Kim; Nicholas J Stanley; James E Farnsworth; Thomas H Kuehn; Peter C Raynor
Journal:  Am J Infect Control       Date:  2011-05-06       Impact factor: 2.918

4.  Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL.

Authors:  Cecylia Łukaszuk; Elżbieta Krajewska-Kułak; Andrzej Guzowski; Wojciech Kułak; Bogumiła Kraszyńska
Journal:  Int J Environ Res Public Health       Date:  2017-07-20       Impact factor: 3.390

  4 in total